My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0082410
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
12 (STATE ROUTE 12)
>
13550
>
4200/4300 - Liquid Waste/Water Well Permits
>
SR0082410
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 3:48:04 PM
Creation date
9/3/2020 2:37:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
SR0082410
PE
4231
FACILITY_NAME
13550 HWY 12
STREET_NUMBER
13550
Direction
W
STREET_NAME
STATE ROUTE 12
City
LODI
Zip
95242
APN
05502002
ENTERED_DATE
7/31/2020 12:00:00 AM
SITE_LOCATION
13550 W HWY 12
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1.3.7.4.3.We recommend that you use one of our strap systems with 1.3.7.4.7.See Table 1-5 for typical deadmen dimensions for tanks <br /> our factory-supplied deadmen. (other than 10-foot-diameter tanks with a capacity greater than 25,000 <br /> 1.3.7.4.4.When installing any size tank,and when using our D-ring/D- gallons[95,000 liters],given the following scenario: <br /> ring anchor straps and prefabricated deadmen,the deadmen are to be an empty tank <br /> placed so that their tops are even with the bottom of the tank.See Figure • a 3-foot[91-cm]burial depth <br /> 1-6 and Table 1-4 for anchor-point dimensions when using our deadmen. • groundwater to grade <br /> • For 8-foot-,10-foot-and 12-foot-diameter tanks,an option when using • 1containmentsump <br /> D-ring/D-ring straps is to place the deadmen on the bedding so the <br /> bottoms of the deadmen are even with the bottom of the tank. <br /> • This is not recommended for 4-foot-and 6-foot-diameter tanks. Tank Diameter Typical Deadmen Dimensions(Width x Depth) <br /> 1.3.7.4.5.The width and thickness of a deadman depends 6-foot 12"[30 cm] x 12"[30 cm] <br /> on the following: 8-foot 12"[30 cm] x 12"[30 cm] <br /> • tank diameter <br /> • water-table elevation 10-foot 18"[46 cm]x 9"[23 cm] <br /> • number of containment sumps 12-foot 36"[91 cm] x 8"[20 cm] <br /> • burial depth <br /> 1.3.7.4.6.The total length of a deadman(on each side of the tank) 1.3.7.4.8.Tanks with more than 1 containment sump and 10-foot-di- <br /> is typically equal to the length of the tank. ameter tanks with a capacity greater than 25,000 gallons[95,000 liters] <br /> • Our prefabricated deadmen come in various lengths. may require either a deeper burial or deadmen <br /> • Dead men are to be butted together end to end on each side of the larger than those shown in Table 1-5.Contact technical support <br /> tank when multiple sections are used. (ena.support@zcl.com)for further information. <br /> • Depending on the installation,multiple deadmen may be required 1.3.7.4.9.The minimum spacing between tanks must be increased <br /> and are to adhere to the following: to accommodate deadmen. <br /> The total length of the assembled deadmen must be appropriate <br /> forthe installed tank. 1.3.7.4.10.Always provide sufficient clearance to allow the <br /> Each section of assembled deadmen must contain at least two deadmen to be set outside the tank"shadow"See section 1.3.5 <br /> balanced anchor points. for tank spacing information. <br /> An equal number of deadmen is required on both sides 1.3.7.4.11.For placement of prefabricated deadmen, <br /> of the tank. see Figure 1-2. <br /> • Our prefabricated deadmen are supplied with 3/4-inch-diameter g <br /> galvanized adjustable anchor points(subsequently referred 1.3.7.4.12.Some contractors use the deadmen as a construction <br /> to as anchor points).See Figure 1-10. guide for proper depth of bedding. <br /> These anchor points protrude up through the slots in the deadmen 1.3.7.4.13.If our prefabricated 18-inch-[45 cm]wide low-profile <br /> and are temporarily supported with cotter pins. deadmen are used as a construction guide,they may need to be <br /> A WARNING elevated.This can be accomplished by putting 3'/2 inches[9 cm]of <br /> Only use the anchor points when lifting and positioning the backfill or a 4x4 piece of wood(or equivalent)underneath so that <br /> deadmen.A spreader bar may be required to lift longer sections the top of the deadmen is 12 inches[30 cm]off of the bottom of the <br /> of deadmen.Use guide ropes to guide the deadmen when lifting. excavation.See Figure 1.11. <br /> Failure to do so could result in death or serious injury. Figure 1-11 <br /> Figure 1-10 <br /> Backfill 18"Wide Low Profile Deadmen <br /> Chain or Sling o o a 3,/z a 4x4 <br /> 6o°to 90° <br /> Anchor Point Anchor Point =IIIII= IIIII=I�� <br /> NOTE:Low-profile deadmen are not 12 inches[30 cm]high. <br /> Alignment Slot Alignment Slot 1.3.7.5.TURNBUCKLES <br /> 1.3.7.5.1.We also offer a turnbuckle that will connect the <br /> deadman anchor point to the FRP anchor strap.See Figure 1-8. <br /> When the deadman is properly positioned,this will eliminate <br /> the use of wire rope.See section 1.3.7.2 for more detail <br /> on anchor straps. <br /> 12 <br />