My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2501
>
2300 - Underground Storage Tank Program
>
PR0231488
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2021 5:31:32 PM
Creation date
9/8/2020 11:58:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231488
PE
2361
FACILITY_ID
FA0003910
FACILITY_NAME
H&M - BW #98
STREET_NUMBER
2501
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
CURRENT_STATUS
01
SITE_LOCATION
2501 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
185
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM(Page 1 of 1) <br /> Type of Action Installation Inspection 0 Inspection Repair Ins <br /> p p ❑36 Month Inspection <br /> 1. FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10181511 111/7/19 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> H&M Market <br /> Business Site Address City ZIP Code <br /> 2501 Jackson Ave I Escalon 95320 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection(Print as shown on the ICC Certification.) Phone# <br /> Kristopher Bell 1(408)971-2445 <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 485184 18833000 7/22/20 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certifications.) <br /> F.F.#1004933708 <br /> OPW#902968 <br /> III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method Manufacturer Guidelines(Specify): <br /> Used: Defender <br /> ❑Industry Code or Engineering Standard(Specify): <br /> ❑Engineered Method(Specify): <br /> Attach the Inspection procedures and all documentation required to determine the results. #of Attached Pages <br /> TANK ID:(By tank number,storedproduct,etc.) 2-Premium <br /> What is the tank inside diameter?(Inches) 96 <br /> Is the fill piping secondarily contained? ❑Yes ❑No ❑Yes m No ❑Yes ❑No ❑Yes ❑No <br /> Is the vent piping secondarily contained? ❑Yes ❑No ❑Yes ©No ❑Yes ❑No ❑Yes ❑No <br /> Overfill Prevention Equipment Manufacturer(s) EBW Defender <br /> What is the overfill prevention equipment response ❑Shuts Off Flow ®Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow <br /> when activated? <br /> (Check all that apply.) ❑Restricts Flow ❑Restricts Flow ❑Restricts Flow ❑Restricts Flow <br /> ❑AN Alarm ❑AN Alarm ❑A/V Alarm ❑AN Alarm <br /> Are flow restrictors installed on vent piping? <br /> ❑Yes ❑No [I Yes ❑✓ No El Yes ❑No El Yes ❑No <br /> At what level in the tank is the overfill prevention set <br /> to activate?(Inches from bottom of tank.) 84 1/8" <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 93% <br /> Is the overfill prevention in proper operating condition ❑Yes ®Yes ❑Yes ❑Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑No(Specify in V.) ❑No(Specify in V.) ❑No(Specify in V.) ❑No(Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ❑Pass ❑Fail I m Pass ❑Fail I ❑Pass ❑Fail ❑Pass ❑Fail <br /> V. COMMENTS <br /> Any items marked'Fail"must be explained in this section. Any additional comments may also be provided here. <br /> Completed Overfill Inspection due to Drop lube Replacement. <br /> RECEIVED <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipmentwas inspected In accordance with California6QW)ft tions,Title 23, <br /> Division 3,Chapter 16,Section 2637.2 and all the Information contained herein is accurate. <br /> UST Service Technician Signature <br /> !L ENVIRONMENTAL HEALTH <br /> If the facility has more components than this form accommodates,additional copies of this page maybe a9OK <br /> CERS=California Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=international Code Cound,AtV=Audible and Visual <br />
The URL can be used to link to this page
Your browser does not support the video tag.