Laserfiche WebLink
3� ' fes „y„•)�� <br /> �f <br /> TLS-350 Monitoring System Requirements Assist ISD <br /> •TLS-350 with ECPU2 Part Numer Description Requirement <br /> •NVMEM 203 330020-445 Assist Vapor Flow Meter Kit 1 per dispenser <br /> •RS-232 Interface Module for On-site PC report access 330020-515 Wired Vapor Pressure Sensor Kit' <br /> •Smart Sensor Module 861190-201 NEW Wireless Vapor Pressure Sensor Kit' 1 per site <br /> •Dispenser Interface Module(DIM) 330020-715 NEW Vapor Pressure Sensor Site Start-up Kit' <br /> 332250-110 Seven Input Smart Sensor Modules <br /> •ISD Software Enhancement Module(SEM) 1 per seven or eight <br /> 329356-004 Eight Input Smart Sensor Module Smart Sensors <br /> •Site Shutdown Control Hardware <br /> Alarm Table Balance ISD <br /> The following table contains a list of warnings and alarms posted or Part Numer Description Requirement <br /> Used by the ISD system: 330020-585 Balance Vapor Flow Meter Kit 1 per dispenser <br /> Balance Assist Warning Days to Description <br /> 330020-515 Wired Vapor Pressure Sensor Kit' <br /> ISO ISD Alarm <br /> 861190-201 NEW Wireless Vapor Pressure Sensor Kit' 1 per site <br /> X X ISD DEGRD PRESSURE 30 75”'percentile of 30 days'tillage aew a <br /> pressure that exceeds 0.3 IWC 330020-715 Vapor Pressure SensorSite Start-up Kit <br /> 9511'percentile of 7 days'ullage 332250-001 Seven Input Smart Sensor Module' 1 per seven or eight <br /> X X ISD GROSS PRESSURE 7 <br /> pressure that exceeds 1.3 IWC 329356-004 Eight Input Smart Sensor Module Smart Sensors <br /> X X ISD VAPOR LEAKAGE 7 Containment system leaks at two 847490-315 PMC Port Controller Module' 1 per TLS Console <br /> times the TP 201.3 standard <br /> X X ISD SENSOR OUT 7 Failure of Sensor Self-test TLS-350 Software/Memory <br /> X x ISD SETUP 7 Failure of Setup Test Upgrade Options for ISD <br /> X Hnn:DEGRD COLLECT 7 7-day Degradation AIL Test Part Numer Description Requirement <br /> X Hnn:GROSS COLLECT 1 1-day Gross AIL Test Warning 331500-358 ECPU2,latest V3XX software,NVMEM 203 <br /> Vapor collection flow pertomance 331500-322 Latest V3XX software,NVMEM 203 <br /> X Hnn:FLOW COLLECT 1 is less than 50% <br /> 332966-203 NVMEM 203(report storage) 1 per Console <br /> X ISD VP PRESSURE 1 9011 percentile of 1-day ullage 330160-004 ISD Software Enhancement Module(SEM) <br /> pressure exceeds 2.5 IWC <br /> 331500-353 TLS V3XX software <br /> X ISD VP EMISSIONS 1 Mass emission exceeded the <br /> certified threshold <br /> T <br /> of Vapor Processor EffluentOptional ISD Components <br /> X ISD VP Status 1ssions or Duty Cycle Test <br /> Part Numer Description Requirement <br /> 331408-001 Dispenser Control Module for Single 1 module per <br /> Dispenser Shutdown 4 dispensers <br /> Typical ISD Configuration Itt - <br /> 330020-630 Vapor Pressure Sensor Kit for Mounting 1 per Console <br /> Carbon Canister on Vent Stack' p <br /> i <br /> I <br /> I <br /> t 1 per Pressure Sensor <br /> 330020-716 Universal Enclosure Box when mounted on <br /> Dispenser Island Vent Stack <br /> I <br /> 330020-717 NEW Vapor Pressure Sensor Drying Tube Kit Replacement Part <br /> TLS Console ISD-moi <br /> Pressure 1. Can only be used on wired installations. <br /> Sensor <br /> wrenctosure 2. Can only be used on wireless installations. <br /> pnstallalion I 3. Required when ordering 861190-201 sensor for wireless installations. <br /> ISD I t I option 2) I 4. Only required for VST Vapor Processors. <br /> Flowmeter 1 1 1 1 wired or I <br /> a r I I 5.At least one seven channel module required when installing Carbon Canister Vapor <br /> 11 I E r Wireless I Polisher,optional on all other ISD sites. <br /> rlll <br /> __----___.-� JIrL---------J I <br /> ISD Pressure Sensor <br /> (Installation Option 1) <br /> Wired Only To learn more,contact us at 888561.7942, or visit www.veeder.com. <br /> V EEDE^Cts_�OOI 1125 Powder Forest Drive,PO.Box 2003,Simsbury CT 06070 USA <br /> (,� �/ 02013 Veeder-Root Company • 576047-065 Rev.F • Printed in USA <br />