My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
16500
>
2300 - Underground Storage Tank Program
>
PR0231554
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2021 3:06:23 PM
Creation date
9/10/2020 8:28:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231554
PE
2361
FACILITY_ID
FA0005678
FACILITY_NAME
LATHROP SHELL
STREET_NUMBER
16500
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
16500 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN :JOAQUIN Environmental Health Department <br /> COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> LATHROP SHELL 16500 S HARLAN RD, LATHROP February 12, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br /> inspections at least once every 30 days at this facility and are including all of the required information on the reports. <br /> This is a minor violation. <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inch. <br /> The 87 product VMI line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of <br /> detecting a 3-gallon per hour leak at 10 psi. The service technician adjusted the leak detector, retested it, and it <br /> passed. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 320 CCR 2635, 2637.2, 2665, 2712 Failure to comply with the installation, inspection, or record keeping of the overfill <br /> prevention. <br /> Owners or operators of underground storage tanks that do not meet California Code of regulations, title 23 division <br /> 3, chapter 16 section 2635(c)(2)shall test overfill prevention equipment once by October 13th, 2018 and every 36 <br /> months thereafter; and within 30 days of the date of a repair.The site did not performed the testing by October 13th, <br /> 2018 however the service technician on site was able to conduct the overfill prevention equipment inspection today <br /> (2/12/19)while the inspector was on site. Ensure to conduct overfill prevention equipment inspection within the time <br /> frame provided by the regulation and submit test results within 30 days of performing the inspection. Ensure a 48 <br /> hour notification is provided to EHD prior to conducting the inspection. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by March 14th, 2019. <br /> Document reviewed: Monitoring system certification test results from 2016, 2017, 2017 Secondary containment <br /> 2018, employee training, response plan, maintenance records, monitoring plan, financial responsibility <br /> documents and designated operator monthly inspection reports from February 2018-January 2019. <br /> Documents provided: Return to compliance certification. <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> appointment, please call (209) 468-3420. <br /> FA0005678 PR0231554 SCO01 02/12/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 6 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.