Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> OVERFILL, PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1 ) <br /> Type of Action El installation Inspection ❑ Repair Inspection ❑ 36 Month Inspection <br /> 1 . FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10/8/2019 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> Shell <br /> Business Site Address City ZIP Code <br /> 620 VV - WrIWI LV-41pr Pklll) je, is V4 Stockton 95206 <br /> 11 . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone It <br /> Chris Adams (209 ) 461 - 6337 <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 1001331 XHAZ 8230218 4/17/2020 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> OPW Cert# 100305 Exp 5/23/2021 <br /> III . OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑x Manufacturer Guidelines (Specify): <br /> Used : <br /> ❑ Industry Code or Engineering Standard (Specify): <br /> ❑ Engineered Method (Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages <br /> TANK ID : (By tank number, stored product, etc.) Diesel 87 <br /> What is the tank inside diameter? (Inches) 92 " 91 <br /> to <br /> Is the fill piping secondarily contained ? ❑ Yes 0 No ❑ Yes E No ❑ Yes ❑ No ❑ Yes ❑ No <br /> Is the vent piping secondarily contained? ❑ Yes El No ❑ Yes 2 No ❑ Yes ❑ No ❑ Yes ❑ No <br /> Overfill Prevention Equipment Manufacturer(s) OPW OPW <br /> What is the overfill prevention equipment response ❑x Shuts Off Flow Z Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow <br /> when activated? ❑x Restricts Flow 0 Restricts Flow ❑ Restricts Flow ❑ Restricts Flow <br /> (Check all that apply.) <br /> ❑ AN Alarm ❑ AIV Alarm ❑ AN Alarm ❑ AN Alarm <br /> Are flow restrictors installed on vent piping? ❑ Yes 0 No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> At what level in the tank is the overfill prevention set <br /> to activate? (Inches from bottom of tank.) 801 /2 80112 <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 93 % 93 % <br /> Is the overfill prevention in proper operating condition ❑x Yes 21 Yes ❑ Yes ❑ Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑ No (Specify In V.) ❑ No (Specify in V.) ❑ No (Specify in V.) ❑ No (Specify in V.) <br /> 1V. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results 0 Pass ❑ Fail 19 Pass ❑ Faii ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked 'Fail' must be explained in this section. Any additional comments may also be provided here. <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected In accordance with California Code of Regulations , Title 23 , <br /> Division 3 , Chapter 16, Section 2637. 2 and all <br /> the Information contained herein Is accurate. <br /> UST Service Technician Signature � .rYGZ®GJ�'Yld� <br /> If the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = International Code Council, AN = Audible and Visual <br />