SAN J O A Q U I N Environmental Health Department <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Mossdale Chevron 444 W MOSSDALE RD LATHROP June 13 2019 <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3), Suction piping not properly sloped or incorrectly located check valve V R COS <br /> 2641(b) <br /> 402 CCR 2643(d) No monitoring or record maintenance for single-walled conventional suction systems(pre-Jan 1984). �V i-,R COS <br /> 403 CCR 2643(d),2661(f) Failure to conduct 0.1 gph test for single-walled conventional suction systems(pre-Jan 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e), 2661(f) Biennial 0.1 gph line integrity test for single-walled gravity piping not performed(pre-Jan 1984) V R COS <br /> Other Violations <br /> 2010 1 See below Unlisted General violation V R COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 HSC 25292.2, 25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br /> An approved copy of financial responsibility documents were not available for inspection. Financial documents on site <br /> are outdated. A copy of these documents shall be accessible on site at all times. Immediately locate and retain a <br /> copy on site. <br /> This is a minor violation. <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> The UST Tank Information forms for the 87, 91 and diesel tanks are not current in CERS. Tank manufacturer <br /> information is missing. Any change of information must be updated in CERS within 30 days of the changes. <br /> Immediately log into CERS, update the required information, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 107 CCR 2632(d), 2641(h), 2711(a) Plot plan/site map not submitted or failed to completely show where monitoring is <br /> performed. <br /> An accurate UST Monitoring Site Plan was not submitted. A site plan must be submitted identifying the location of the <br /> annular space sensor. Immediately log into the California Environmental Reporting System (CERS) at <br /> http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> This is a minor violation. <br /> 109 CCR 2637(a-d), 2712 Failed to test secondary containment, or failed to maintain test records for 36 months. <br /> According to the designated operator's monthly inspection reports and test results onsite, secondary containment <br /> testing was last performed on 3/27/2016 and was due by March 2019 . Testing has not been completed and is 3 <br /> months past due. Secondary containment testing is required once every 36 months. Immediately schedule this test <br /> and provide 48 hours notification to the EHD. <br /> This is a Class II violation. <br /> FA0000212 PR0231692 SCO01 06/13/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />