Laserfiche WebLink
" , Environmental Health Department <br /> SAN J OAQ U I N <br /> " ! ` COUNTY Kasey Foley, REHS , Interim Director <br /> °gtiFo4... Greatness grows here . PROGRAM COORDINATORS <br /> - - Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> Michael Kith , REHS <br /> Melissa Nissim , REHS <br /> November 7 , 2019 <br /> Guadalupe Sanchez <br /> Diamond Petroleum Services , Inc . <br /> 3619 King Ct , <br /> Antioch , CA 94509 <br /> Re : ARP Mini Mart Corp . SR0081248 <br /> 25775 S . Patterson Pass Rd . , Tracy , CA 95376 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a 1 hour plan check service request to replace the 87 master and 91 spill containers , in <br /> fill sumps , on the underground storage tank ( UST) system at the above noted address . The plan <br /> check service request has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust (d,) sjgov . org for the following repairs and testing ( a 48 - hour <br /> notice is required ) . Please be aware that inspections for emergency work must be scheduled <br /> within five days of plan check service request approval . <br /> a . Spill bucket test : Verify minimum 5 -gallon capacity and pass a one hour hydrostatic test ( or <br /> equivalent) . Proper drainage must also be verified . <br /> Please be aware that the facility cannot receive fuel in the 87 master or 91 tanks prior to <br /> completion of passing spill bucket testing and submission of notification of passing test <br /> results to the EHD . <br /> 4 . If concrete will be broken near the tanks or piping , a secondary containment test must be <br /> performed on the affected components once concrete is poured in accordance with the <br /> manufacturer' s guidelines , and test results submitted to the EHD within 30 days of testing . <br /> 5 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be issued <br /> to the installation company) , or a Tank Tester' s license issued to the individual by the State <br /> Water Board , and <br /> b . Possess or work under the direct and personal supervision of an individual physically <br /> present at the work site who possesses a valid , current California UST Service Technician <br /> certificate issued by the International Code Council ( ICC) , and <br /> c . Possesses a valid , current certificate of training from the manufacturer(s ) of the <br /> component (s) being tested , repaired , or serviced . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 T 209 468-3420 1 F 209 464 -0138 1 www . sjgov . org/ehd <br />