My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4501
>
2300 - Underground Storage Tank Program
>
PR0231233
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/25/2020 2:29:11 PM
Creation date
9/11/2020 2:54:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231233
PE
2361
FACILITY_ID
FA0002479
FACILITY_NAME
7-ELEVEN INC #17334
STREET_NUMBER
4501
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11017004
CURRENT_STATUS
01
SITE_LOCATION
4501 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
141
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Overfill Prevention Equipment Inspection <br /> .1114Tanknology OPW 61 and 71 Series Overfill Prevention Device Inspection <br /> Date: 11/17/2020 <br /> Customer Name: 7-ELEVEN, INC. <br /> Location#: 7-ELEVEN#17334 MKT 2368(N-747) <br /> Location Address: 4501 N.PERSHING AVE.@ ROSEMARIE LN. ,STOCKTON CA, 95207 <br /> OPW Model Number: 71so <br /> T-2 T-1 <br /> PART 1)Proper height setting calculation <br /> Maximum Tank Volume per:Tank Chart Agallons 10028.000 10028.000 <br /> Max shut off requirement for Flapper is 95% a 95% 0.95 0.95 0.95 0.95 <br /> Multiply Maximum tank volume by 95% c gallons 9526.600 9526.600 <br /> Use tank chart to determine height of calculated volume D inches 86.500 86.500 <br /> Measure top of fill riser threads,or face seal adapter when used,to tank top E inches 30.000 27.000 <br /> Tank diameter From Chart Finches 96.000 96.000 <br /> Upper Tube in tank(G) F-D=G G inches 9.500 9.500 <br /> Subtract 2 inches from upper tube in tank G-2"=H H inches 7.500 7.500 <br /> Calculated minimum upper tube length(1)H+E=I i inches 37.500 34.500 <br /> Actual measured upper tube length (Without fill <br /> J inches 37.500 34.750 <br /> adapter)(J) <br /> PART 2)Device certification criteria evaluation <br /> Criteria 1 Yes Yes <br /> Does the overfill prevention device meet the 95%requirement? <br /> Criteria 1 a If the final shutoff volume is installed greater than 95%,is there at <br /> least 250 gallons of ullage above the overfill device activation point NA NA <br /> to ensure that none of the tank top fittings are exposed to product, <br /> meeting the criteria established in EPA 280.20iic and per OPW <br /> installation guidelines. <br /> Criteria 2 Is the Actual measured upper tube length 6.5 inches Yes Yes <br /> or more than the fill riser?(J must be 6.5"or more <br /> than E) <br /> Criteria 3 Does the overfill prevention device function as <br /> required?(Inspect the device for damage, Yes Yes <br /> contamination,freedom of movement, <br /> weakening due to wear and corrosion) <br /> PART 3)Device Certification PASS/FAIL <br /> Pass Pass <br /> Technician certifies that the device is operationally <br /> compliant. <br /> Comments: <br /> Signature of <br /> t <br /> Technician: Date: 11/17/2020 <br /> Tim Elebeck <br /> WO: NW1-2348553 <br />
The URL can be used to link to this page
Your browser does not support the video tag.