Laserfiche WebLink
is E or <br /> San Joaquin a l l HEALTHY AIR LIVING' <br /> vwww,haalthyairliving.cam <br /> AIR POLLUTION CONTROL DISTRICT Make one change for clean' air! <br /> TP 201.3 <br /> UST Static Pressure Performance Test Report Form <br /> Permit Number:N-747-1-6 Test Company:Tanknology Inc. <br /> Site Name: 7-ELEVEN#17334 MKT 2368(N-747) Technician: Tim Elebeck <br /> Site Address:4501 N.PERSHING AVE.@ ROSEMARIE LN. Certification Number Expiration Date <br /> City:STOCKTON Zip: 95207 District: <br /> Date/Time of Test:7/27/2018/ <br /> TEST INFORMATION <br /> Total number of nozzles:4 Are the tanks manifolded?P Yes ! No <br /> Phase I vapor recovery system executive order(as referenced on Permit to Operate) VR 102 <br /> Phase II vapor recovery system executive order(as referenced on Permit to Operate) IVR 202 <br /> Nitrogen introduction point ❑Phase I Vapor Coupler F100 Phase II Vapor Riser <br /> Pressure measuring device ❑Incline Manometer F47 Digital Manometer F. .Mechanical Gauge <br /> Calibration date for pressure measuring device(must be within 90 days of the test) 6/4/2018 <br /> Ending value for digital manometer drift test if applicable(must be 0.01 in.w.c.or less) 0.00 <br /> Initial tank ullage pressure(vent if over 0.5 in w.c.) -5.57 <br /> Nitrogen introduction flow rate, F(must be between 1 and 5 CFM) 2.00 <br /> Calculated ullage fill-time,tz 02=V/1522 x F) 03:19 <br /> Actual fill-time 03:21:00 <br /> Number of hoses with over 100 ml(balance hoses must be drained prior to testing) <br /> TANK INFORMATION <br /> Tank No. 1 1 ALL <br /> Product grade 87 87 <br /> Actual tank capacity(gallons) 10028 10028 20056 <br /> Gasoline volume(gallons) 5938 4015 9953 <br /> Ullage,V(gallons) 4090 6013 10103 <br /> If tanks are not manifolded,number of nozzles 4 <br /> 2 IN.W.C.STATIC PRESSURE TEST <br /> Test No. 1 2 5 <br /> Start time 10:50:00 <br /> Initial Pressure, inches of water column(in.w.c.) 2.00 <br /> Pressure at one minute,in.w.c. 1.98 <br /> Pressure at two minutes,in.w.c. 1.97 <br /> Pressure at three minutes,in.w.c. 1.96 <br /> Pressure at four minutes,in.w.c. 1.95 <br /> Pressure at five minutes,in.w.c. 1.94 <br /> Allowable minimum pressure, in.w.c. 1.90 <br /> Pass/Fail(enter"GF"for gross failure) Pass <br /> 1 declare, under penalty of perjury under the laws of the state of California that based on information and belief formed after reasonable inquiry, the <br /> statements and information provided in the document are true, accurate,and complete. <br /> Signature of Technician: �a „y Date:7/27/2018 <br /> WO:2338028 Ver. 1.0—12.26.07 <br />