Laserfiche WebLink
10 -3 1/2• Pill <br /> 40_60 5'-21/2' Q NOTES UST INSTALLATION <br /> 1 SLOPE CONCRETE AWAY FROM ALL MANHOLES 1 " RISE OVER 12• RUN, DESIGN <br /> 0 0 0 0 2FIBER REINFORCEMENT TO BE USED, PREMIX UNIFORMLY THROUGHOUT A re h T t e D t u r a l <br /> O CONCRETE Solutions Group <br /> OREINFORCING BARS TO BE NO LESS THAN 2" AND NO MORE THAN 4" FROM <br /> SURFACE, 24.55 Berxlelt Va3ey Rd. Wta A-102 <br /> 12 , 000 GALLON - PREMIUM UNLEADED 10 , 000 GALLON - DIESEL , B O REINFORCE CONCRETE SUB AROUND MANHOLE WITH (4) =4 RERAR 60" IN soma Rosa. cA. 9546 <br /> 8" B" 8• g' LENGTH. PUCE REBAR 6" FROM SIDES OF BOX, <br /> 16-1/2" 16-1/2" SINGLE 1 " CONDUIT TO EACH SUBMERSIBLE PUMP. PROVIDE SEAL-OFF AT <br /> O SUMP & BUILDING WIRING TROUGH. CONTAINS UNE VOLTAGE WIRING, ALL <br /> REF, [ re te te REF. REF. CONDUIT PENETRATIONS MUST BE MADE WITH ROBROY PVC COATED CONDUIT EDARC <br /> _ c° ONLY. y �SaS N91 <br /> g 42' Ol4 FILL w a 48" DIA TURBINE Cr <br /> SUMP ¢ 22" DIA 22 � SUMP ONE l " STANDARD MONITORING HOMERUN CONDUIT TO EACH TANK. y. <br /> MANWAY I \ FOR STANDARD MONITORING DEVICES, LOOP CONTAINMENT SUMP <br /> BRINE RESERVOIR SENSORS, PLLD, VAC SENSORS & TANK GAUGE TO TANK INTERSTITIAL RB1. 1 /31/19 <br /> AND INTERSTITIAL O SENSOR LOCATION AND HOMERUN TO BLDG. PROVIDE SEAL-OFFS IN <br /> o MONITOR ° ° ° °0\= ° �° BUILDING & PRIOR TO LEAVING HAZARDOUS AREA ROUTE TO <br /> p _ INTRINSICALLY SAFE TROUGH IN BUILDING. CONDUITS SHALL CONTAIN <br /> �t ,i ^ o� , , o-. � ® @ ONLY LOW VOLTAGE WIRING FOR SENSORS, ALL CONDUIT PENETRATIONS <br /> ) MUST BE MADE WITH ROBROY PVC COATED CONDUIT ONLY. Sed 9rFOFCAllFO`A <br /> Oi.° ° !°/ ° a USE PEA GRAVEL CONSISTING OF NAlURA11Y ROUNDED A(X;REGATE, MIN Y" <br /> ' ' ANCHOR STRAP & MAX OF Y4" IN SIZE, FREE OF CLAY, SLAG, CINDERS, OR DEBRIS. ALL <br /> \ ° ° / 4 LOCATION (TYP.) OO SUBSTITUTES MUST BE APPROVED BY MANUFACTURERS & OWNER'S FIELD bp <br /> 42" DIA FILL REPRESEWATNE. <br /> 48" DIA TURBINE SUMP TANK WEIGHT <br /> SUMP Q NOT USED. <br /> 2, 625 LBS DRY <br /> 169900 LBS W/BRINE Q NOT USED, <br /> TANK PAD MINIMUM 2'-0" OFF OUTSIDE WALLS OF TANKS, AND MUST <br /> / COVER THE FOOTPRINT OF THE TANKS, REQUIRED TO PROVIDE FOR PROPER <br /> — TANK HOLD DOWN, AND TO PREVENT ACCIDENTAL DRIWNG INTO TANK, <br /> CW CORNER WHERE MEETING ASPHALT PAVING ONLY, SQUARE CORNERS <br /> WHERE MEETING CONCRETE <br /> o REFER TO SITE SPECIFIC PLANS FOR ACTUAL PIPE RUNS & NUMBER OF <br /> PRODUCT LINES (1 OR 2 PER UST SUMP), <br /> OPTIONAL MANUFACTURER 16 1 2" TURBINE AND FILL SIDE SUMP CONFIGURATION SHOWN M TYPICAL FOR <br /> SUPPLIED 18'x8k18' 14 1'-8" 2'-2" 1 '-g' / (TYP,) INSTALLATION <br /> LA DESIGN CRITERIA AT THESE SUMPS SEE ACCOMPANYING TANK <br /> INSTALLATION SIZE PIAN & SUMP DETAIL DRAWINGS NOTED ABOVE. <br /> DFADMAN (TYP. OF 4) 6'-10 1/2" T-2" e-1 1/2• 4'-11" 5'-9 1/2" 6'-10 1/0 5'-6 1/4" O TANK ANCHORING OPTIONAL. CONSULT LOCAL REGULATION; VERIFY WITH <br /> OWNER'S REPRESENTATIVE. <br /> 41'-3 1/4" OVERFLOW PROTECTION: UST OVERFLOW COMPUAME IS ACHIEVED BY USE OF ¢ <br /> OVERFLOW PREVENTION DROP TUBE FLAPPER VALVE SET AT 95% AND IS IN <br /> ACCORDANCE WITH FEDERAL AND STATE GUIDEIINES FOR UST OVERFILL <br /> UNDERGROUND TANK PLAN VIEW <br /> REQUIREMENTS, m p p z <br /> DIESEL CONFIGURATION W OPW A B C N rn F o <br /> / us�.fe us>.te „ x , fa AN OVERFILL HARM AND ACKNOWLEDGE SWITCH TIED INTO THE VEEDER ROOT 5 w a <br /> SCALE: 1 /2" = 1 '-0" AUTOMATIC TANK GAUGE SYSTEM. THE MONITORING SYSTEM PROVIDES AN g a~. rr w <br /> AUDIBLE AND VISUAL ALARM WHEN THE TANK(S) ARE FILLED TO THE 90% _ a w y o L m <br /> FOR SINGLE 2 HP ISI ON 12K TANK F G H D E F - Imo - w w o z <br /> (2022 CONFIGURATION) u ° . 11 uca13 NSA.13 715313 ux • 17 us1A Y.5A17 <br /> C D G H FOR DIESEL CONFIGURATION W/ SINGLE 2 HP IST. RTX u o o <br /> 20 INSIDE 3" DOUBLE OINNOCATES TENTS FOUND ON MATERNLS UST SHEETS M.5.3.01 & M.5.3.02 J o o m K <br /> FOR DPW FILLS WAIL FRP VACUUM <br /> ILS1H W5.3.N usau u3J.N _ z F ¢ <br /> CROSSOVER TO FILL D = ¢ <br /> WW m <br /> SUMP FOR VENT & F a ¢ ow <br /> VAPOR CONTINUOUS 1 NOTE m ¢ ¢ ¢ ¢ w ¢ <br /> 1 CHOSE APPLMABLE DRAWINGS E o- ¢ a. m a- <br /> 1 i MONITORING. N - > > r^ <br /> 7• THICK CONCRETE 2 3 q FOR CONFIGURATION. z o 0 0 rn o <br /> SLAB (TYP.) — — IZ5 ASPHALT AND STONE PER Y5G / NOTE: /PROJECT SPECIFICATIONS I53t8 24 / o1 " FRP BONDED CHASE PIPE WITH 3 4 ) 0 1 (IYP.) a N o o ENTRY FITTING VACUUM Tl1BING TO BE 1 (TYP ) - <br /> 10 1 (TYP ) (TYp ) VACUUM MONITORED <br /> .^: E <br /> ddd <br /> � •7 ' 3" PEA •GRAVE MIN. TO• <br /> 1" COAD. LOOP TO SUMP 8 2" INSIDE 3" DOUBLE Uj PREVENT LOAD TRANSFER ' <br /> 89 WALL FRP VACUUM TO TOP OF TANK O F <br /> J-BOX CROSSOVER TO FILL I7 W <br /> 4" FRP RISER TO GRADE 6 I I SUMP FOR VENT & 6" WIDE DETECTABLE UNDERGROUND <br /> �� VAPOR CONTINUOUS MARKING TAPE BURIED 6"-12" <br /> HOME RUN TO 6 6 I MONITORING, q O 5 BELOW FINISH- GRADE EMPIRE m <br /> MAGNATEC 131-14343 Q <br /> BUILDING 5 <br /> DUAL FLOAT C 4 <br /> 1" FRP BONDED 2 24 1 " FRP BONDED z <br /> TNG S IAR0 6 ENTW FITTING 6 ENTRY FITTING <br /> MONITORING ET150R < (TYP,) (ttP ) <br /> Z <br /> HYDROSTATIC 10 TU <br /> - <br /> © I® Q <br /> z{ SLOPE SIDES OF TANK HOLE OR RESERVOIR SUMP SUMP C'7 <br /> S USE SHORING FOR ALL TANK <br /> -EXCAVATIONS IN ACCORDANCE WITH <br /> OSHA 1926 SUBPART P, OSHA j — — — — — — — — — \ \ \. 0 U <br /> STANDARDS - EXCAVATIONS; FINAL I \ \ <br /> RULE OCTOBER 1 , 1989 U <br /> j \\ <br /> 19 EXTRACTOR FITTING 19 EXTRACTOR FITTING I I \� , fr L1_I <br /> S _ <br /> (OVERFILL PROTE ON III I I I I CO \\ \ d <br /> ' I DROP TUBE AT I I I I t4 OGTION TYP 1` a <br /> I BACKFILL WITH PEAGRAVEL I I OVERFILL PROTECTION 0 TANK LEVEL GAUGE W/ 95X ) 0 TANK LEVEL GAUGE W/ I I (R STRAP) <br /> - DROP TUBE SET AT I e FLOAT KR, OVERFILL I I 4" FLOAT KR. OVERFILL I I II <br /> \ \ _ 2 PER TANK MANUFACTURER 0 O I I I ,i <br /> SPECIFICATIONS. 957E (TYP.) ALARA AT 90R 1 41 1 MARM AT 9077 CAPACITY <br /> 41 , I I II II II III I I I , I ISI <br /> ` 10x2ex11GA STEEL STRIKER <br /> / \,\ I I PLATES TYP. UNDER ALL OPENINGS I I I I I I // \\ \ /• <br /> W/ MANWAYS ON FlBERGlA55 TANK <br /> S (BY TANK MANF)� <br /> 99<,, \ \ \\ \ \ 50 0 SwHO V.�SIEEL Fired f4mber <br /> 01 0 \\ PE <br /> 12"x12"x11GA STEEL STRIKER PLATES <br /> of / TYP. UNDER ALL OPENINGS W/0 z / i / SPA16002 . 0 <br /> WL <br /> mos MANWAYS ON (BY TANK TANK <br /> \�\ (BY TANK MMIF.) / <br /> ,: <br /> et Name <br /> vv \\\\ ` <br /> z .- ; . . -. . . �:� �.. . . :. . . <br /> o .. _ _. . _ _. _ 1 0 MIN. PEA GRAVII. .._ - .. . . .. . - . . . . . :.�• �- � �.;ii �.:._'_i' go <br /> _ . . r_ . TRIPPER SCREEN . _. •>' . . ..- . •. . ,': ,:J�:.t .'•. - 09 TRAP ��.;+..' <br /> she <br /> . . ` . . ';� • ER SCREEN <br /> 09 <br /> 7 INSTALLED OVER . (TYP- - <br /> ' 1 GALLON <br /> 2 000 70 000 A <br /> TYPICAL1 <br /> COMPACTED SOIL :��7 <br /> \ � �\ \ .� .~ \` DOUBLE ALL FIBERGLASS TAN <br /> K <br /> b \ \ \ \ \ \ \ NMI <br /> \ \ \ \ � OMNI <br /> \ ; \ 0/m <br /> \ INSTALLATION DETAILS <br /> / \1 / iii/ /�G /\ y y � /moi` / /� /� / i,. . / �/ / / / G <br /> 2, MIN END OF TANK TANK SIZE VARIES WITH MANUFACTURER AND MODEL NUMBER 2 MIN' <br /> ® Sheet Nw ber <br /> A: UNDERGROUND TANK SECTION DETAIL M . �yBC90 � <br /> A SCALE: 1 /2" = 1 '_0" <br />