My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
124
>
2300 - Underground Storage Tank Program
>
PR0231866
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2020 2:49:24 PM
Creation date
9/14/2020 11:25:19 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231866
PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AT&T <br /> AT&T Services, Inc. <br /> Environment, Health & Safety <br /> 5001 Executive Parkway, Room 4W200 <br /> San Ramon, CA 94583 <br /> March 12 , 2019 <br /> Original via e-mail on 3/ 12/ 19 <br /> zbarker@sjcehd. com <br /> Ms . Zuna Barker <br /> San Joaquin County Environmental Health Department <br /> 1868 E . Hazelton Avenue <br /> Stockton, CA 95205 <br /> RE : Required Follow-Up Actions, Your Inspection of 2/ 11 / 19 for AT&T California Facility at <br /> 124 W Elm St, Lodi, CA 95240 (UE020), ITS # 182067 <br /> Dear Ms . Barker : <br /> We are pleased to report status of the corrective actions that you required pursuant to your inspection <br /> referenced above : <br /> I <br /> ➢ Failure to conduct the designated UST operator visual inspection at least once every <br /> 30 days. CCR 2716(a-e) , <br /> Status : COMPLETED. See attached updated Designated Underground Storage Tank <br /> Operator Visual Inspection Reports and Return to Compliance Certification Form . <br /> ➢ Failure to comply with the installation, inspection, or record keeping of the overfill <br /> prevention. The automatic tank gauge used as the overfill prevention was set at <br /> 91 . 6 % and not at or below 90 % as required by regulation. <br /> Status : COMPLETED. The service technician adjusted the tank diameter in the Veeder <br /> Root System to the correct tank diameter to ensure that the audible and visual alarm <br /> activated at 90% . The service technician retested the overfill prevention equipment with <br /> passing results while the inspector was on site during the inspection on 2/ 11 / 19 . <br /> We trust that we are in full compliance with all the requirements that resulted from this inspection. If <br /> you need anything more from us to close this matter, please contact me at the number below. <br /> Sincerely, <br /> / PWJ4 Rw;k Q " /cc& 2 <br /> Vicki Allen <br /> Environmental Manager <br /> Tel : 925 277 6728 <br /> Email : va7457 a att. com <br /> cc : Thuy Tran, Environmental Site Manager <br /> Eric Speas, Area Manager-EH&S <br />
The URL can be used to link to this page
Your browser does not support the video tag.