Laserfiche WebLink
7500 GALLON LOW PROFILE <br /> BATTERY SEPTIC TANK <br /> MODEL 3XJP2500 <br /> 24" CAST IRON FRAME AS REQUIRED <br /> (AT EXTRA CAST) <br /> X-11"--AND COVER WITH GASKET <br /> f (GASTIGHT) OPTIONAL, AT <br /> T EXTRA COST 2432-03 RISER-3" -� <br /> VARIABLE 2432-06 RISER-6" <br /> 12" MIN. 24 DIA, 2432-12. RISER-12"-� <br /> CLEAR OPENING <br /> EACH END <br /> INVERTr TT INLET INVERT <br /> OUTLET <br /> 4" INLET & 4.-9.. <br /> SIDE VIEW OUTLET <br /> 3'-8" CUTAWAY PIPE AND 3'-5" <br /> FITTINGS ARE <br /> STANDARD <br /> *2x6 REDWOOD GRADE BOARDS <br /> (SUPPLIED BY OTHERS) <br /> LAYING LENGTH 50'-1" <br /> 16'-7" 16'-7" 16'-7" <br /> r - - -LF -1-1- - -TOP <br /> - - -U- - - -U - - � r - - - - - � - - � <br /> COVERSW ` J `` a l a 7,_8„ <br /> REMOVED I I ` " I <br /> L - - -FL - - - - - - - -r-L - - -. - - J I L — — --FL - - - - - J <br /> ASSEMBLY SEQUENCE <br /> SIDE VIEW <br /> 0 = RECOMMENDED 1 COVER 2 COVER 3 COVER <br /> RISER/CAST IRON INLET 1 BASE 2 BASE 3 BASE OUTLET <br /> COVER LOCATIONS <br /> / 1 = OPTIONAL <br /> l` RISER/CAST IRON <br /> COVER LOCATIONS <br /> FOR INSTALLATION INSTRUCTIONS, LIQUID CAPACITY: 7,500 GALLONS. <br /> DESIGN AND PRODUCT INFORMATION, BOX DESIGN LOAD: H-20 TRAFFIC FROM <br /> CONTACT JENSEN PRECAST. 1' TO 5' OF SOIL COVER. <br /> 11,9/07 Iff"Mon <br /> 7500ST-3XJP2500-B.dwg <br /> 02007 Jensen Precost PRECAST® <br />