My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WAGNER HEIGHTS
>
4000
>
2900 - Site Mitigation Program
>
PR0545798
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/14/2020 5:55:57 PM
Creation date
9/14/2020 4:23:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0545798
PE
2950
FACILITY_ID
FA0005305
FACILITY_NAME
OCONNER WOODS
STREET_NUMBER
4000
STREET_NAME
WAGNER HEIGHTS
STREET_TYPE
RD
City
STOCKTON
Zip
95209
CURRENT_STATUS
02
SITE_LOCATION
4000 WAGNER HEIGHTS RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
75
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Enseco <br /> A CORNING ZG Ga'v <br /> I Sample Description <br /> See the attached Sample Description Information. <br /> The samples were received under chain-of-custody. <br /> II Analysis Request <br /> The following analytical tests were requested. <br /> Lab ID Analysis Description <br /> 056133-1,2 Total Petroleum Hydrocarbons (Gasoline) , BTEX <br /> Total Petroleum Hydrocarbons, Diesel <br /> III Quality Control <br /> A. Project Specific QC. No project specific QC (i .e. , spikes and/or <br /> duplicates) was requested. <br /> B. Method Blank Results. A method blank is a laboratory-generated <br /> sample which assesses the degree to which laboratory operations <br /> and procedures cause false-positive analytical results for your <br /> samples. <br /> No target parameters were detected in the method blanks associated <br /> with your samples at the reporting limit levels noted on the <br /> attached Method Blank Report. <br /> C. Laboratory Control Samples - The LCS Program <br /> Duplicate Control Samples. A DCS is a well -characterized matrix <br /> (blank water, sand or celite) which is spiked with certain target <br /> parameters and analyzed at approximately 10% of the sample load in <br /> order to establish method-specific control limits. The DCS <br /> results associated with your samples are on the attached Duplicate <br /> Control Sample Report. <br /> Accuracy is measured by Percent Recovery as in: <br /> recovery = (measured concentration) x 100 <br /> (actual concentration) <br /> Precision is measured using duplicate tests by Relative Percent Difference <br /> (RPD) as in: <br /> RPD = (% recovery test 1 - % recovery test 2) x 100 <br /> (% recovery test 1 + % recovery test 2)/2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.