Laserfiche WebLink
SAN" J D�l+ �� I 11411" Environmental Health Department <br /> COUNTY— <br /> Underground <br /> �l O U N T Y-- <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Marks Fuel& Food Inc. 880 E VICTOR RD LODI Joctober 09 2019 <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3), Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 2641(b) <br /> 402 CCR 2643(d) Failure to conduct monitoring/maintain records for single-walled conventional suction(pre-1984) ❑V ❑R ❑COS <br /> 403 CCR 2643(d),2661(f) Failure to conduct 0.1 gph test for single-walled conventional suction systems(pre-Jan 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e),2661(f) 0.1-gph line test for single-walled gravity piping not performed biennialy or post repair(pre-1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 HSC 25292.2,25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br /> 1) Financial responsibility documents have not been submitted to the EHD. The most recent financial responsibility <br /> documents in CERS are dated 2/27/2018. Current financial responsibility documents are required to be submitted <br /> annually. Immediately log into the California Environmental Reporting System (CERS)at http://cers.calepa.ca.gov/, <br /> and upload the required documents. <br /> 2)Current financial responsibility documents were not found on site. A copy of current financial responsibility <br /> documents are required to be maintained on site. Immediately obtain a copy of the facility's financial responsibility <br /> documents and maintain a copy on site. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> 105 CCR 2632(d)(1), 2634(d)Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. <br /> -The monitoring plan for the 91 tank incorrectly states the leak detector to be a VMI LD2000.The leak detector <br /> observed on site was a FE Petro STP-MLD. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br /> into CERS, make the necessary changes, and submit for review by the EHD. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> FA0003862 PR0231746 SCO01 10/09/2019 <br /> EHD 23-01 Rev.08/27/2019 Page 4 of 9 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />