COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
2358
>
2300 - Underground Storage Tank Program
>
PR0231756
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/15/2020 11:36:53 AM
Creation date
9/15/2020 10:56:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231756
PE
2361
FACILITY_ID
FA0006343
FACILITY_NAME
STOCKTON MOBIL 3*
STREET_NUMBER
2358
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
14118221
CURRENT_STATUS
01
SITE_LOCATION
2358 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ O A Q U I N Environmental Health Department <br /> - <br /> - - CC UNI Y — - f <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address : Date : <br /> ALPHA FAST GAS * 2358 E WATERLOO RD , STOCKTON June 27 , 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II , or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions . <br /> A designated operator monthly inspections was not performed . The designated operator visual inspections shall be <br /> conducted within 30 days or less of the previous inspection . Ensure that all designated operator inspections are <br /> performed within the required time frames . <br /> This is a minor violation. <br /> 210 CCR 2716 (f) DO monthly reports not maintained on site for 12 months or for 36 months ( after October 1 , 2018 ) . <br /> The designated operator monthly inspection reports were not found on site. Designated operator monthly inspection <br /> reports for the previous twelve months shall be retained on site . Locate and ensure that copies of the previous twelve <br /> months of designated operator monthly inspection reports are maintained on site . Submit copies to the EHD . <br /> This is a minor violation . <br /> 211 CCR 2715 (c) (2 ) No employee present that were trained in the operation and maintenance of the UST system by a <br /> DO . <br /> The designated operator employee training for Deanna Rebultan was not performed or not current . The designated <br /> operator shall train facility employees for which he or she is responsible in the proper operation and maintenance of <br /> the UST system once every 12 months . The training shall include , but is not limited to : <br /> 1 . Operation of the UST system in a manner consistent with the facility ' s best management practices <br /> 2 . Employee ' s role with regard to monitoring equipment as specified in the facility' s monitoring plan <br /> 3 . Employee ' s role with regard to spills and overfills as specified in the facility ' s response plan <br /> 4 . Name of the contact person (s ) for emergencies and monitoring equipment alarms <br /> Ensure that employees have been trained by the designated operator, maintain the list on site , and submit a copy of <br /> the training records to the EHD . <br /> This is a minor violation. <br /> 215 CCR 2712 ( i ) Failure to retain a copy of the permit to operate at the facility . <br /> A copy of the UST operating permit was not found on site . A copy of the UST operating permit and all attachments <br /> and conditions shall be retained at the facility . Immediately obtain a copy of the permit and retain it on site . <br /> This is a minor violation . <br /> 320 CCR 26351 2637 . 21 26651 2712 Failure to comply with the installation , inspection , or record keeping of the overfill <br /> prevention . <br /> Overfill prevention testing has not been conducted . This testing was required to be conducted by October 13 , 2018 . <br /> Immediately schedule this testing and provide 48 hours notification to the EHD . Ensure all future testing is conducted <br /> within required time frames <br /> This is a Class II violation. <br /> Overall Inspection Comments . <br /> FA0006343 PR0231756 SCO01 06/27/2019 <br /> EHD 23-01 Rev. 09/28/2018 Page 7 of 8 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468 -3420 F 209 464-0138 1 www. sjcehd. com <br />
The URL can be used to link to this page
Your browser does not support the video tag.