My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4315
>
2300 - Underground Storage Tank Program
>
PR0231760
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2022 9:20:21 AM
Creation date
9/15/2020 11:25:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231760
PE
2351
FACILITY_ID
FA0003831
FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ OA U I Environmental Health Department <br /> COUNTY <br /> — <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> WATERLOO FOODMART 4315 E WATERLOO RD STOCKTON Aril 30 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> The designated operator failed to check and note all required items on the visual inspection reports. The incorrect and <br /> missing information included the following from the inspection reports: <br /> -Section V was left blank. <br /> -CERS ID was left blank. <br /> -Overfill test information was left blank. <br /> -The reports incorrectly mark that all follow up to previously reported issues were completed and list repeat issues in <br /> Section III. <br /> -Overfill test date was left blank. <br /> -Section VI was left blank. <br /> During the visual inspection, the designated operator shall check that all required testing and maintenance for the UST <br /> system have been completed and shall check all required items on the report. Ensure that designated operators <br /> performing visual inspections at this facility are including all of the required information on the reports. <br /> This is a Class II violation. <br /> 215 CCR 2712(1) Failure to retain a copy of the permit to operate at the facility. <br /> A copy of the UST operating permit was not found on site. A copy of the UST operating permit and all attachments <br /> and conditions shall be retained at the facility. Immediately obtain a copy of the permit and retain it on site. <br /> This is a Class II violation. <br /> 314 HSC 25290.1, 25290.2, 25291 Failed to have secondary containment or secondary containment not tight. <br /> The S3 (91 line)sensor has been in no vacuum alarm since May 6, 2019. Secondary containment shall be impervious <br /> to the liquid and vapor of the substance contained and constructed to prevent structural weakening as a result of <br /> contact with any hazardous substances released from the primary containment. Immediately contact a properly <br /> licensed, trained, and certified contractor to make repairs to the UST system under permit and inspection of the EHD. <br /> A permit application (SR0080525) has been received by EHD for repairing a damaged product pipe, but has not yet <br /> been accepted. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Witnessed testing of the 87 and 91 spill containers on April 30, 2019. Both passed. Verified 5 gallon capacity. <br /> This testing completed the annual monitoring inspection which was due by April 2019. <br /> Sensor functionality, VPH communication, and leak detector testing were conducted on March 25, 2019 under <br /> SR0078796; that testing will serve as the initial portion of the annual inspection, resetting the inspection due date <br /> to March 2020. <br /> The paperwork inspection was completed on May 30, 2019. <br /> An inspection checklist was provided to the facility operator on the day of inspection. The EHD has written the <br /> complete report which replaces the initial checklist. <br /> FA0003831 PR0231760 SCO01 04/30/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 5 Of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.