Laserfiche WebLink
U E058 <br /> UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM ( Page 1 of 1 ) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection I] 36 Month Inspection <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10181547 2/9/2019 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> Pacific Bell Telephone Co . dba AT&T California <br /> Business Site Address City ZIP Code <br /> 10 E . 12th St. Tracy 95376 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone # <br /> Gage hart (714) 560-8222 <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 588098 8361014 06/ 12/2019 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> veeder-Root TLS-XX Technician <br /> III . OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑ Manufacturer Guidelines (Specify) : <br /> Used : <br /> ❑x Industry Code or Engineering Standard (Specify) : PEI RP1200 <br /> ❑ Engineered Method (Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. 76f Attached Pages <br /> TANK ID : (By tank number, stored product, etc.) UE0580002 <br /> What is the tank inside diameter? (Inches) 95 . 750 <br /> Is the fill piping secondarily contained ? 0 Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> Is the vent piping secondarily contained ? ❑x Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> Overfill Prevention Equipment Manufacturer(s) Veeder-root <br /> What is the overfill prevention equipment response ❑ Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow <br /> when activated ? <br /> ❑ <br /> (Check all that apply.) Restricts Flow El Restricts Flow ❑ Restricts Flow El Restricts Flow <br /> ❑x AN Alarm ❑ AN Alarm ❑ AN Alarm ❑ AN Alarm <br /> Are flow restrictors installed on vent piping ? ❑ Yes ❑x No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> At what level in the tank Is the overfill prevention set <br /> to activate? (Inches from bottom of tank.) 80 . 750 <br /> What is the percent capacity of the tank at which the <br /> overfillp revention equipment activates? 90% <br /> Is the overfill prevention in proper operating condition 0 Yes nEl <br /> El Yes El Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑ No (Specify in V.) pecifyin V) ❑ No (Specify in V.) ❑ No (Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results D Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked "Fail" must be explained in this section. Any additional comments may also be provided here. <br /> El Check If Action Item (s) Are Present <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> 1 hereby certify that the overfill prevention equipmentwas inspected in accordance with California Code of Regulations , Title 23 , <br /> Division 3 , Chapter 16, Section 2637 . 2 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> lew *Wwa <br /> If the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = Intemational Code Council, AN = Audible and Visual <br />