My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1001
>
2300 - Underground Storage Tank Program
>
PR0231876
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/15/2020 2:15:15 PM
Creation date
9/15/2020 1:30:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231876
PE
2361
FACILITY_ID
FA0000421
FACILITY_NAME
DINO MART
STREET_NUMBER
1001
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1001 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1 ) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection x❑ 36 Month Inspection <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10180593 10/ 11 /2018 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> MONTEREY FUELING <br /> Business Site Address TMANTECA <br /> ity ZIP Code <br /> 1001 E YOSEMITE AVE CA 95336 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) TVhone # <br /> David Winkler 1 (209 ) 744- 0112 <br /> Contractor I Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 08- 1739 8883059 - UT 1 /29/2020 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> FF- EBW , Phil-Tite & EVR Phase 1 1009853708 Ex 11 - 16- 18 OPW 104-633 Ex 3- 14-2020 <br /> Emco #3207 Ex . 09-21 -2020 VR : B34975 ATG : 2/8/20 <br /> III . OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑x Manufacturer Guidelines (Specify) : <br /> Used : REMOVED DROP TUBES - OPW <br /> ❑ Industry Code or Engineering Standard (Specify) : <br /> ❑ Engineered Method (Specify) : <br /> Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages 5 <br /> TANK ID : (By tank number, storedproduct, etc.) 87 91 DSL <br /> What is the tank inside diameter? (Inches) 92 92 92 <br /> Is the fill piping secondarily contained? ❑ Yes ❑x No ❑ Yes ❑x No ❑ Yes R No ❑ Yes ❑ No <br /> Is the vent piping secondarily contained? ❑ Yes [E No ❑ Yes ❑x No ❑ Yes 0 No ❑ Yes ❑ No <br /> Overfill Prevention Equipment Manufacturer(s) OPW OPW OPW <br /> 61SO 61SO 61SO <br /> What is the overfill prevention equipment response ❑x Shuts Off Flow ❑x Shuts Off Flow ❑x Shuts Off Flow ❑ Shuts Off Flow <br /> when activated ? <br /> (Check all that apply.) El Restricts Flow ❑ Restricts Flow El Restricts Flow El Restricts Flow <br /> ❑ AN Alarm ❑ AN Alarm ❑ AN Alarm ❑ AN Alarm <br /> Are flow restrictors installed on vent piping ? ❑ Yes (] No ❑ Yes N No ❑ Yes H No ❑ Yes ❑ No <br /> At what level in the tank is the overfill prevention set <br /> to activate? (Inches from bottom of tank.) 821 /2 821 /2 91 <br /> What is the percent capacity of the tank at which the 95 99 <br /> overfill prevention equipment activates? 95 <br /> Is the overfill prevention in proper operating condition ❑x Yeses YEl Yes El Yes <br /> to respond when the substance reaches the <br /> appropriate level ? ElNo (Specify in V.) ❑ No (Specify in V) ❑x No (Specify in V.) El (Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results 0 Pass ❑ Fail I ❑x Pass ❑ Fail ❑ Pass Z Fail ❑ Pass ❑ Fail <br /> V. COMMENTS mp <br /> Any items marked "Fail' must be explained in this section. Any additional comments may 'd/sotbO provided 00 <br /> DSL DROP TUBE FLAPPER IS TOO HIGH . NEEDS REPLACED ASAP <br /> ',j 0 2i11 �1 <br /> .� A'( <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUg <br /> I kTAI I E, <br /> I hereby certify that the overfill prevention equipmentwas inspected in accordance WO a i orrnia_4 =or e'Qf qgu afions, Title 23, <br /> Division 3 , Chapter 16 , Section 2637 . 2 and all the information contained herein is accurate . 1 ) \ - I i '' I <br /> UST Service Technician Signature <br /> If the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = Intemational Code Council, AN = Audible and Visual <br /> I <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.