My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
7272
>
2300 - Underground Storage Tank Program
>
PR0231939
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/15/2020 3:50:25 PM
Creation date
9/15/2020 3:05:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231939
PE
2361
FACILITY_ID
FA0002570
FACILITY_NAME
QUIK STOP MARKET #3144
STREET_NUMBER
7272
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
094-040-13
CURRENT_STATUS
01
SITE_LOCATION
7272 WEST LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM (Page 1 of 6) <br /> This form must be used to document testing and servicing of underground storage tank (UST) monitoring equipment. A copy <br /> of this form must be provided to the UST owner or operator. The owner or operator must submit a copy of this form to the local <br /> agency regulating the USTs within 30 days of the date of the monitoring system certification . <br /> 1 . FACILITY INFORMATION <br /> CERS ID Date of Monitoring System Certification <br /> 10180967 1 7/ 18/2019 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) Building # <br /> Quik Stop Market # 144 144 <br /> Business Site Address City ZIP Code <br /> 7272 West Ln Stockton 95210 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Company Performing the Certification Phone # <br /> Walton Engineering , Inc . ( 916 ) 372 - 1888 <br /> Mailing Address <br /> P . O . Box 1025 , West Sacramento , CA 95691 <br /> Name of UST Service Technician Performing the Certification (Print as shown on the ICC Certification) <br /> Max Hines , Ron McEntee <br /> Contractor I Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 617238 8750053 11 /9/2019 <br /> Monitoring System Training and Certifications List all applicable certifications. Expiration Date <br /> Veeder- Root <br /> Va orless - VMI <br /> Ill . RESULTS OF TESTING I SERVICING <br /> Indicate and attach the following reports if the monitoring equipment is capable of generating either. Y N NA <br /> 0 Monitoring System Set-up QX Alarm History Report <br /> Was any monitoring equipment replaced ? <br /> (If "Yes, " identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below.) El FX El <br /> Was damage , debris , or liquid found inside any secondary containment systems? <br /> (If "Yes, " describe what was found in section IV below.) X El El <br /> Is all monitoring equipment operational per manufacturer's specifications ? FX1 ❑ EJ <br /> (If "No. " describe why in section IV below.) <br /> IV. COMMENTS <br /> If directed to use this section, describe how and when the issues were or will be corrected. <br /> Removed roughly 14 gallons from 89 grade fill sump and about 8 gallons from 87 fill sump . Also removed small amount of <br /> residual liquid from all three STP sumps . <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> hereby certify that the equipment identified in this document was inspected/serviced in accordance with California Code of <br /> Regulations , Title 23 , Division 3 , Chapter 16 , Section 2638 and all information contained herein is true and accurate. Attached to <br /> this certification is information (e.g . , manufacturers' checklists , monitoring system set-up, alarm history report, etc . ) necessary <br /> to verify that this information and the site plan showing the layout of UST system is complete and accurate . <br /> UST Service Technician Signature <br /> CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Coundl, Y = Yes, N = No, NA = Not Applicable <br />
The URL can be used to link to this page
Your browser does not support the video tag.