My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2300 - Underground Storage Tank Program
>
PR0231945
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/15/2020 4:26:22 PM
Creation date
9/15/2020 3:17:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231945
PE
2361
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Existing l / 7 Edsting UDC's - Typical of 3 <br /> Cnlbarco EMC � (3) ea-isting UDC's <br /> to have Bravo float <br /> and chain shear valve <br /> shut off assembly's <br /> removed <br /> Remote annunciator O <br /> All work will take place at the fuel island on the (3) existing UDCs. <br /> 1D00 <br /> Existing 15kUnleaded tar& <br /> T <br /> STP O 000 <br /> Existing UDC s repaired and retrofitted - Typical of 3 <br /> O New 5404 sensor will temrinate at new <br /> O DC4044 Controller installed at existing <br /> dispenser J box Typical of 3. <br /> Ddsting 5k diesel tank <br /> F,xTosed or corroded surfaces to be sanded <br /> cleaned and coated with AmerSbield. <br /> Scope: Notify SJEHD HazMat 48hr in advance of performing work on site. <br /> Secure work area, de-energize equipment. Remove existing Bravo float <br /> and chain, shear-valve shut-off from (3) existing dispensers. Supply and <br /> install Bravo B-2000 Float Cup Retrofit kits to each of (3) existing UDCs. <br /> Make repairs to exposed or corroded sufaces in all UDCs using AmerShield. - - <br /> Supply and install (3) new INCON DC400 dispenser cutoff controllers with <br /> S404 liquid sensors to provide dispenser shutdown on alarm conditions. fUNew Bravo B2000 FG Retrofit Cup typical of 3 <br /> Schedule and demonstrate operation for SJEHD HazMS40 <br /> at. New 4 Liquid Sensor typical of 3 <br /> Equipment: (3) Bravo FCRK 1 lA B2000 Float Cup Retrofit Kits <br /> (3) Incon DC404 S404 liquid sensor and controller <br /> ( 1 ) AmerShield 2-Component, polyester-acrylic topcoat. <br /> LOCATION: DRAWING <br /> LLNL Bldg 879 S- 1 <br /> Corral Hollow Road REV Date <br /> Tracy, CA 95376 <br /> � 1 .2 10-1 -19 <br /> THORNTONENVIRONMENTAL CONSTRUCTION Origin <br /> P.O. Boa 360833FT <br /> Milpitas, CA 95036 <br /> PHONE 209-8340792 Scale <br /> 40&946-1015 None <br /> FAX 209.8340795 <br />
The URL can be used to link to this page
Your browser does not support the video tag.