My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2300 - Underground Storage Tank Program
>
PR0231945
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/15/2020 4:26:22 PM
Creation date
9/15/2020 3:17:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231945
PE
2361
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br /> Type of Action ❑Installation Inspection ❑Repair Inspection 10 36 Month Inspection <br /> 1. FACILITY INFORMATION <br /> CERS ID 10154767 Date of Overfill P�ev�Atigp6 6pment Inspection <br /> B siness Name( ame as Facility a e or D Din 8 siness As) t1 L 1`J <br /> Lawrence Livermore ITa�iona, agora ory Bldg. 879 <br /> eCo�a1SHol?orAl Road Nacy5376 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN_INFORMATION <br /> N e of Uf Seryce Technician Performing the Inspection(Print as shown on the ICC CertYication.) Phone 09-834-0792 <br /> 9'r fan' I horn on <br /> Contra /T T to i n ICC Certificat ICC Certificatio E at' to <br /> CSLffX,t-�b�AL #724513 �6�4962-UT YWM 0 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certrficallons.) <br /> EMCO Wheaton #3253 Exp. 11-16-2020 OPW#104777 Exp. 3-14-2020 Veeder Root Cert#A31562 Exp. 6-7-2019 <br /> Ill. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ®Manufacturer Guidelines(Specify): <br /> Used: <br /> ®Industry Code or Engineering Standard(Specify): PEI 1200 <br /> ❑Engineered Method(Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. #of Attached Pages 1 <br /> TANK ID: (By tank number,stored product,etc.) Uiesel Unleaaed <br /> What is the tank inside diameter?(Inches) <br /> Is the fill piping secondarily contained? ❑Yes ®No ❑Yes ®No ❑Yes ❑No ❑Yes ❑No <br /> Is the vent piping secondarily contained? ❑Yes ®No ❑Yes ®No ❑Yes ❑No ❑Yes ❑No <br /> Overfill Prevention Equipment Manufacturer(s) <br /> What is the overfill prevention equipment response ®Shuts Off Flow ®Shuts Off Flow ❑Shuts Off Flow ❑ Shuts Off Flow <br /> when activated? <br /> (Check all that apply.) ❑ Restricts Flow ❑Restricts Flow ❑Restricts Flow ❑ Restricts Flow <br /> ®AN Alarm ®A/V Alarm ❑AN Alarm ❑A/V Alarm <br /> Are flow restrictors installed on vent piping? ©Yes ❑No ®Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> At what level in the tank is the overfill prevention set85 �� 118 011 <br /> to activate?(Inches from bottom of tank.) <br /> What is the percent capacity of the tank at which the 93.5% 96.5% <br /> overfill prevention equipment activates? <br /> Is the overfill prevention in proper operating condition ®Yes j❑Yes ❑Yes ❑Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑No(Specifyin V.) No(Specify in V.) ❑No(Specify in V.) ❑No(Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results 19 Pass ❑Fail I ❑Pass ® Fail I [:]Pass ❑ Fail ❑ Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked"Fail"must be explained in this section. Any additional comments may also be provided here. <br /> The Gilbarco audible visual alarm sits above the door on outside of main building facing both tanks. <br /> Gilbarco alarms are set at 90% and 95% of eadh tanks capacity. <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the ovefill prevention equipment was inspected in accordance with California Code of Regulations,Title 23, <br /> Division 3,Chapter 16,Section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> �7 If the facility has more components than this form accommodates,additional copies of BWpage may be attached. <br /> CERS=California Environmental Reporting System,ID=Identification,UST=Underground Storage Tank ICC=International Code Council,AAl=Audible and Visual <br /> UN-109 www.unidocs.org 111-Rev.06114118 <br />
The URL can be used to link to this page