My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2300 - Underground Storage Tank Program
>
PR0231945
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/15/2020 4:26:22 PM
Creation date
9/15/2020 3:17:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231945
PE
2361
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1 ) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection 1936 Month Inspection <br /> I. FACILITY INFORMATION <br /> CERS ID 10154767 q Date of Overfill P,�WY6iYST6pment Inspection <br /> BLsawre"nce (Livermore IVaiIonal Laboratory AS) Bldg . 879 �� <br /> 8T996b Wbor�al Hollow Road Iracy 95ft <br /> ��nn t(�7 11. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> NtS(l onf I Service <br /> r ice Technician Performing the Inspection (Print as shown on the /CC Certification.) Phone 09-834-0792 <br /> L , - L '°�� C Cert�catio Date <br /> 513 � 820Contrat/ TAnXT to� #724ICC Cerfifca <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable cerifficaSons.) <br /> EMCO Wheaton #3253 Exp. 11 - 16-2020 OPW #104777 Exp. 3- 14-2020 Veeder Root Cert #A31562 Exp. 6-7-2019 <br /> III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ® Manufacturer Guidelines (Specify): <br /> Used: <br /> ® Industry Code or Engineering Standard (Specify): <br /> ❑ Engineered Method (Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages j <br /> TANK ID: (By tank number, stored product, etc.) less n ea e <br /> What is the tank inside diameter? (inches) 960011 <br /> Is the fill piping secondarily contained? ❑ Yes 10 No ❑ Yes ® No ❑ Yes ❑ No ❑ Yes ❑ No <br /> Is the vent piping secondarily contained? ❑ Yes ® No ❑ Yes ® No ❑ Yes ❑ No ❑ Yes ❑ No <br /> Overfill Prevention Equipment Manufacturer(s) <br /> What is the overfill prevention equipment response ® Shuts Off Flow ® Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow <br /> when activated? <br /> (Check all that apply.) ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow <br /> ® AtV Alarm ® AA1 Alarm ❑ AIV Alarm ❑ A/V Alarm <br /> Are flow restrictors installed on vent piping? ® Yes ❑ No ® Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> At what level in the tank is the overfill prevention set 8 j Orr 107 .5" <br /> to activate? (inches from bottom of tank.) <br /> What is the percent capacity of the tank at which the 90% 90% <br /> overfill prevention equipment activates? <br /> Is the overfill prevention in proper operating condition ® Yes ® Yes ❑ Yes ❑ Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑ No (Specify in V.) ❑ No (Specify /n V.) ❑ No (Specify in V.) ❑ No (Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ® Pass ❑ Fail ® Pass ❑ Fail ❑ Pass ❑ Fall ❑ Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked Fail" must be explained in this section. Any additional comments may also be provided here. <br /> This report reflects inspection and testing of the Gilbarco audible / visual alarm and annunciator. <br /> The Gilbarco audible visual alarm sits above the door on outside of main building facing bAtanks. <br /> Gilbarco alarms are set at 90% and 95% of each tanks capacity. <br /> Demonstrated for SJEHD . <br /> EOr <br /> ss 7 r <br /> tP <br /> 11 P <br /> Vi . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INS POTION <br /> 1 hereby certify that the overfill prevention equipmentwas inspected in accordance with California Code'diVIkeduiakio §, Title 23, <br /> Division 3 , Chapter 16, Section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signature ENVIRONMENTAL 114 P r j <br /> If the facility has more components an this form accommodates, additional copies of this page may be attached i\, r <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = International Code Council, AN = Audible and Visual <br /> UN409 www.unidoes.org 111 - Rev. 06114118 <br />
The URL can be used to link to this page
Your browser does not support the video tag.