Laserfiche WebLink
°P"? , SAN 10AQUIN a <br /> Environmental Health Department <br /> ' t '� COUNTY - <br /> Linda Turkatte , REHS , Director <br /> iFoa�'�P Greatness grows here . Kasey Foley, REHS , Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Rodney Estrada , REHS <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> August 23 , 2019 <br /> Matt Thomas <br /> CGRS , Inc . <br /> 5444 Dry Creek Rd . <br /> Sacramento , CA 95838 <br /> Re : United # 5446 SR0080777 <br /> 1403 Country Club Blvd . , Stockton , CA 95204 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a permit to replace the direct- bury 87 spill container, the 87 drop tube , the waste oil fill <br /> sump manway , and the waste oil spill container ( in a fill sump) on the underground storage tank ( UST) <br /> system at the above noted address . The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Contact Stacy Rivera at (209 ) 468- 3440 to arrange the following inspection appointments ( a <br /> 48 - hour notice is required for inspection appointments ) . Please be aware that inspections for <br /> emergency work must be scheduled within five days of permit approval . <br /> a . Corrosion protection : Verify corrosion protection for 87 direct bury spill bucket prior to <br /> backfilling . <br /> b . Spill bucket test : Verify minimum 5 -gallon capacity and pass a one hour hydrostatic test ( or <br /> equivalent) for 87 and waste oil spill containers . Proper drainage must also be verified . <br /> c . Overfill prevention verification : Measurement of 87 drop tube to verify 95 % tank volume <br /> shut off. Verification of flapper functionality . Ensure that all pertinent tank charts and <br /> calculations are available for review at the time of inspection . <br /> d . Verification that ball float (s ) , if installed , do not interfere with the installed 87 flapper valve . <br /> e . Since concrete will be broken near the 87 and waste oil tanks , a secondary containment <br /> test must be performed on these tanks once concrete is poured in accordance with the <br /> manufacturer' s guidelines . <br /> Please be aware that the facility cannot receive fuel in the 87 tank prior to the EHD <br /> inspection and approval . <br /> 4 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be issued <br /> to the installation company) , or a Tank Tester' s license issued to the individual by the State <br /> Water Board , and <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 F 209 464 -0138 1 www . sjcehd . com <br />