My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1033
>
2300 - Underground Storage Tank Program
>
PR0232352
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2021 9:50:01 AM
Creation date
9/15/2020 4:39:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0232352
PE
2361
FACILITY_ID
FA0003829
FACILITY_NAME
VANCO TRUCK-AUTO PLAZA
STREET_NUMBER
1033
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16323041
CURRENT_STATUS
01
SITE_LOCATION
1033 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
90
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1 ) <br /> Inspection <br /> El 36 Month Inspection <br /> Type of Action ❑ Installation Inspection ElRe air P Ins P <br /> I . FACILITY INFORMATION <br /> Date of Overfill Prevention Equipment Inspection <br /> CERS ID 6/26/2019 <br /> Business Name (Same as Facility Name or DBA Doing Business As) <br /> Vanco Truck and Auto Plaza ZIP Code <br /> Business Site Address City <br /> 1033 W Charter Way Stockton 95206 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone(209) 461 -6337 <br /> Contractor / Tank Tester License # <br /> ICC Certification # ICC Certification 1Expiratiion Date <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> III . OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑ Manufacturer Guidelines (specify): <br /> Used : <br /> 0 Industry Code or Engineering Standard (Specify): <br /> ❑ Engineered Method (Specify): <br /> # of Attached Pages <br /> Attach the inspection procedures and all documentation required to determine the results, <br /> TANK ID : (By tank number, stored product, etc.) Diesel S <br /> What is the tank inside diameter? (Inches) 119 . 5 <br /> Is the fill piping secondarily contained ? EI Yes El No <br /> El Yes [I No El Yes El No El Yes [I No <br /> Is the vent piping secondarily contained? ❑ Yes No El Yes [I No El Yes El No ❑ Yes El No <br /> Overfill Prevention Equipment Manufacturers) Overfill Alarm <br /> V/R <br /> What is the overfill prevention equipment response El Shuts Off Flow El Shuts Off Flow [I Shuts Off Flow Shuts Off Flow <br /> when activated? ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow <br /> (Check all that apply.) <br /> 0 All Alarm ❑ AIV Alarm ❑ AN Alarm ❑ AN Alarm <br /> Are flow restrictors installed on vent piping? Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> At what level in the tank is the overfill prevention set <br /> to activate? (Inches from bottom of tank.) <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? <br /> Is the overfill prevention in proper operating condition ❑x Yes ❑ Yes El es ❑ Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑ No (Specify in <br /> V.) ❑ No (Specify in V.) ❑ No (Specify in V.) ❑ No (Specify in V.) <br /> We SUMMARY OF INSPECTION RESULTS all <br /> Fail Pass ❑ Fail <br /> Overfill Prevention Inspection Results Pass ❑ Fall <br /> E] pass ❑ <br /> Pass Fa ❑ <br /> Fail ❑ ❑ <br /> .lMl Ilia <br /> V. COMMENTS <br /> Any items marked Fail' must be explained in this section. Any additional comments may also be provided here. <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipmentwas inspected in accordance with California Code of Regulations , <br /> Title 23 , <br /> Division 3 , Chapter 16 , Section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> If the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = Ceifomia Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = International Code Council, AN = Audible and Usual <br />
The URL can be used to link to this page
Your browser does not support the video tag.