Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM ( Page 1 of 6) <br /> Type of Action ❑ Installation Test ❑ Repair Test ❑ Six Month Test 0 36 Month Test <br /> 1 . FACILITY INFORMATION <br /> CERS ID Date of Secondary Containment Test <br /> 10181461 8/ 16/2019 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> Vanco Truck & Auto Report 1 of 2 <br /> Business Site Address City ZIP Code <br /> 1033 West Charter Way Stockton 1 95206 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test (Print as shown on the /CC Certification) Phone # <br /> Benjamin Duncan ( 707 ) 621 - 0378 <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> Afford -aAest/90- 1120 5246802- UT 3/20/2021 <br /> III . SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> TANK ID : (By tank number, stored product, etc.) A T- 1 - Race 100 B T-2-91 C T-3 - Regular 87 D T4-Diesel South <br /> Tank Containment <br /> Tightness Test Result E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA O Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA <br /> Product Piping Containment <br /> Tightness Test Result E Pass ❑ Fail ❑ NArPassl ❑ NA E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA <br /> Communication Test Result E Pass ❑ Fail ❑ NAl ❑ NA E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA <br /> Remote Fill Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail E NAl E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA <br /> Communication Test Result ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA <br /> Vent Piping Containment <br /> Tightness Test Result E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA <br /> i <br /> Communication Test Result E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA <br /> i <br /> Vapor Recovery Piping Containment <br /> Tightness Test Result E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail E NA <br /> I <br />[ Communication Test Result E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA O Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail E NA <br /> Turbine 1 Product Piping Sump <br /> Tightness Test Result E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA <br /> Fill Riser Sump <br /> Tightness Test Result E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA <br /> f <br />' VENT I TRANSITION SUMP ID : a b C d <br /> Tightness Test Result ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA <br /> UDC ID : 1 1 &2 2 3&4 3 5&6 4 7-Satelite <br /> Tightness Test Result E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA <br /> UDC ID : 5 7&8 6 8&9-Satelite 7 9& 10 8 10-Satelite <br /> Tightness Test Result E Pass ❑ Fail ❑ NA [HI Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA <br /> UDC ID : 9 11 -Satelite 10 11 & 12 11 12& 13-Satelite 12 13& 14 <br /> Tightness Test Result E Pass E] Fail E] NA E Pass E] Fail ❑ NA E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA <br /> All items marked "Fail' or "NA " must be explained in their respective "COMMENTS" section. <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the secondary containment was tested in accordance with California Code of Regulations , Title 23 , Division <br /> 3 , Chapter 16 , Section 2637 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> _� "_.N�"" <br /> O <br /> i' <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = International Code Coundl, NA = Not Applicable, UDC = Under- <br /> Dispenser Containment <br /> iI <br />