Laserfiche WebLink
WALTON <br /> ENGINEERING , INC. <br /> P. 0. Box 1025 9163721888 PH <br /> 3900 Commerce Drive 9163731172 FAX <br /> West Sacramento, CA 95691 -1025 CA Contractor's License # 617238 <br /> Customer Job Location Work Order # 120614 <br /> Quik Stop Markets, Inc. Quik Stop Market #152 Z1 Scheduled Date: 6/14/2019 <br /> 4567 Enterprise Street 1721 S . Cherokee Lane #1 Scheduled Time : 10: 00: OOAM <br /> Fremont, CA 94538 Lodi , CA 95240 Contact: Michael Karvelot <br /> Customer PO# : C-1 -0001 <br /> Phone: 2093697375 Facility: W31020-152 <br /> Station # : 152 <br /> Contract # : <br /> Work To Be Performed : Call type: Test - Monitoring System <br /> Annual Compliance Test <br /> Work Performed : <br /> 6/13/19 JSA has been attached to W0. <br /> 6/13/19 Performed annual MSC with inspector present, everything but the Diesel Float and Chain in disposer 34 passed . Removed 55 gallons of <br /> water from the Diesel Fill sump. The 87 and 91 Fill sumps still contain water. Someone from Walton Eng will return tomorrow to remove <br /> water and repair the float and chain assembly. Replaced the fill cap on the Diesel product before achieving a passing result. MSC test water <br /> and any removed parts and ]quid were left in owner and Walton supplied drums. Owner suppled drum is dated 44-19 and is full . Walton <br /> supplied drum was dated today and is 1 /4 full . Solid drum was dated today and is 1 /4 full . <br /> 6/14/19 Completed and uploaded the JSA to the Walton work order. <br /> 6/14/19 Replaced the Diesel Bravo Float in Disp #3-4 then performed a function <br /> test with passing results. Placed Disp #34 Diesel product back to service. <br /> Disposed of old float in an on site solid hazardous waste drum. ASD 6-13-19 (1 /4 Full) <br /> Removed about 170 Gallons of liquid from the 87 and 91 Fill Sumps. <br /> Disposed of in Walton supplied liquid hazardous waste drums. <br /> ASD 1 -4-19 - 100% Full, ASD 6-13-19 - 100% Fu]], ASD 6-14-19 - 100% Full, ASD 6-14-19 - 100% Ful], ASD, <br /> 6-14-19 - 100% Full, ASD 6-14-19 - 1 /4 Full <br /> Open Problems: <br /> 6/13119 1 ea 302-91017 - Bravo - FA-FLOAT - Round Float Assembly MS=O Tony R. =1 <br /> 6/13/19 The Diesel float in dispesnser 3-4 was taking on water and needs to be replaced. This is a special order part. The Sheer valve was left in <br /> the tripped position and the diesel nozzles at fueling positions 3-4 were bagged off until the repair is completed tomorrow. Water remains in <br /> the 87 and 91 fill sumps. I would guess there is 65 gallons of water) between the two fill sumps that needs to be removed . A technician from <br /> Walton Eng will return tomorrow to repair the float and chain assembly and remove the water from both Fill sumps. <br /> Parts Used : <br /> Qty Part # Mfg Mfg Part # New Serial # Desc Reason <br /> 1 301 -14011 OPW 634TT-7085-EVR N/A Cap, 4" Fill, EVR OPW Normal Wear <br /> 1 309-51011 RES1 DRUM, 55 GAL., DOT N/A Drum, 55 Gal. DOT, UN1A2, Open Top New <br /> 1 309-72090# ACCU MHZWCA N/A Label, Hazardous Waste Decal for Drums New <br /> 4 309-5101 l RES 1 DRUM, 55 GAL., DOT Drum, 55 Gal. DOT, UN1A2, Open Top <br /> 5 309-72090# ACCU MHZWCA Label, Hazardous Waste Decal for Drums <br /> 1 302-91017 BRAVO FA-FLOAT Round Float Assembly <br /> Date Technician Arrival Departure Date Dchnician Arrival Departure <br /> 6/13/19 Carpenter; Curtis D. 08:26 1 14:17 16/14/19 1 Jauregui Jr.;Juan J. 8:55 11 :50 <br /> 6/13/19 Olvera III; Henry S. 08:26 14:17 6114/19 Olvera III; Henry S. 8:55 11 :50 <br /> i <br /> I <br />