Laserfiche WebLink
SAN JOA UIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT <br /> 304 E.We Ave.,Third Floor a Stockton,CA 95202-2708 a Phone(209)469-3420 <br /> Donna Horan, R.E.H.S., Director <br /> ENVIRONMENTAL HEALTH <br /> SAN OAQUIN COUNTY CERTIFIED UNIFIED PROGRAM AGENCY <br /> PERMIT TO OPERATE <br /> Program Permit Permit <br /> Record ID Number Program Code and Description Valid <br /> PRO518884 PT0012246 2220-SMALL QUANTITY HAZARDOUS WASTE GENERATOR FACILITY 1/1/2003 To 12/31/2003 <br /> Hazardous Waste Generator Program: <br /> California Health and Safety Code,Div.20, hap.6.5,Art_2-13,Sec.25100 et seq,and Title 22,California Code of Regulations,Chap.20. <br /> ------------------------ ----- ----------------- <br /> PR0231094 2300-UNDER ROUND STORAGE TANK FACILITY 1/1/2003 To 12/31/2003 <br /> Underground Storage Tank Program: <br /> California Health and Safety Code,Div.20, hap.6.7 and Title 23,California Code of Regulations,Chap. 16. <br /> -------------- <br /> P/E Tank# Tank Record ID Fcrrtit# Capacity Contents Permit Status System Type Leak Detection <br /> 2360 9 390002310940504854 P 0007419 10,000 PREMIUM UNLEADED Active,billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> 2360 8 390002310940504853 P 0007418 10,000 REGULAR UNLEADED Active,billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> 2360 7 390002310940504852 PT0007417 10,000 REGULAR UNLEADED Active,billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> 2362 6 390002310940504851 PT0007416 10,000 REGULAR UNLEADED Active,billable DOUBLE WALLED Continuous Inlerstilial Monitoring <br /> BOA fi79:74,0 <br /> Underground Storage Tank Permit Conditions <br /> 1) The Permit to Operate will become void ifAnnual Permit Fees and Service Fees are not paid and/or the UST system(s)fails to remain in compliance with these Permit Conditious. <br /> 2) In order to maintain the operating permit,the ownct and operator shall comply with the H&S Code,Div.20,Chap.6.7 and 6.75;and CCR,Title 23,Chap.16 and 18,as well as any conditions <br /> established by San Joaquin County. <br /> 3) If the Tank Operator(s)is different from the Tan`1 Owner,or if the Permit to Operate is issued to a person other than the owner or operator of the lank,the Permittee shall ensure that both <br /> the Tank Owner and tank Operator receive a copy of the permit. <br /> 4) Written Monitoring Procedures and an Emergency esponse Plan must be approved by the Environmental Health Department(EHD)and are considererd UST Pemiit Conditions. The approved <br /> monitoring,response,and plot plans shall be nein ncd onsite with the permit <br /> 5) The Permittee shall comply with the monitoring pr edures referenced in this permiL <br /> 6) The Permittee shall perform testing and preacnliv�e maintenance on all leak detection monitoring equipment annually,or more frequently ifspecified by the equipment manufacturer,and <br /> provide documentation of such servicing to this olTice. <br /> 7) In the event of a spill,leak•or other unauthorized release,the Permilee shall comply with the requirements of Title 23 CCR.Chap.16,Art.5,and the approved Emergency Response Plan. <br /> 8) Written records of all monitoring performed shalllbc maintained on-site by the operator and bc available for inspection for a period of at least three years from the date the monitoring was <br /> Performed. <br /> 9) The EHD shall be notified of any change in owners ip or operation of the UST system within 30 days of such change. <br /> 10) Upon any change in equipment,design or operati n of the UST system(including change in tank contents or usage),the Permit to Operate will be subject to review,modification or <br /> 1 1) CetY/lgi gfbn,repair and/or removal pcmii(s are req ired from the EHD prior to any change,repair or removal of UST system equipment. <br /> 12) The Permittee shall submit an annual report docucoling compliance with the UST Permit Conditions within 30 days of the anniversary date of the issuance of this permit. <br /> 13) This Permit to Operate shall not be considered pe fission to violate any laws,ordinances or statutes of any other Federal.State or Local agency. <br /> 14) A"Conditional'Permit may be revoked if core tions specified on the inspection report are not completed by the date(s) indicated. <br /> PERMITS TO OPERATE are NOT TRANSFERABLE <br /> and may be SUSPENDED or REVOKED for cause. <br /> PERMIT(s)Valid only for: BP WEST COAST PRODUCTS LLC <br /> Tank Owner: BP WEST COAST PRODUCERS LLC <br /> THIS FOWNII MUST BE DISPLAYED CONSPICUOUSLY ON THE PREMISES <br /> Regulated Facility: ARCO STATION #2130 <br /> Facility ID FA0003632 <br /> 7906 N EL DORADCI ST Account ID AR0003210 <br /> STOCKTON, CA 5207 Issued 5/1/2003 <br /> Billing Address: ATTN : RALPH MORAN <br /> BP WEST COAST RODUCTS LLC <br /> PO BOX 6038 <br /> ARTESIA, CA 9 702-6038 <br /> 7023.rpt <br />