My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOWER SACRAMENTO
>
18806
>
2300 - Underground Storage Tank Program
>
PR0232388
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2022 10:16:19 AM
Creation date
9/17/2020 11:24:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0232388
PE
2361
FACILITY_ID
FA0003607
FACILITY_NAME
WOODBRIDGE AM PM*
STREET_NUMBER
18806
Direction
N
STREET_NAME
LOWER SACRAMENTO
STREET_TYPE
RD
City
WOODBRIDGE
Zip
95258
APN
01543010
CURRENT_STATUS
01
SITE_LOCATION
18806 N LOWER SACRAMENTO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM ( Page 1 of 1 ) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection ® 36 Month Inspection <br /> 1 . FACILITY INFORMATION <br /> CERS ID 10181237 Date of Overfill Prevention Equipment Inspection <br /> 19/26/ 18 <br /> Business Name (Same as Facility Name or DBA-Doing Business As.) <br /> WOODBRIDGE AMPM <br /> Business Site Address City ZIP Code <br /> 18860 LOWER SACRAMENTO RD WOODBRIDGE, CA 95258 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone # <br /> DAVE WINKLER 209 744 - 0112 Ext. <br /> Contractor/Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 08- 1739 8883059-UT 1 - 31 -20 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> FF- EBW Phil-Tite & EVR Phase 1 1009853708 Ex 11 - 16- 18 OPW 104-633 Ex 3- 14-2020 Emco #3207 Ex. 09-21 -2020 VR: B34975 ATG: 2/8/20 <br /> III . OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method Used : M Manufacturer Guidelines (Specify) Removed Drop Tubes <br /> ❑ Industry Code or Engineering Standard (Specify) <br /> ❑ Engineered Method (Specify) <br /> Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages : 3 <br /> Tank ID : (By tank number, stored product, etc.) 87 91 DSL <br /> What is the tank inside diameter? (Inches) 96 96 96 <br /> Is the fill piping secondarily contained ? [3d Yes ❑ No M Yes ❑ No [M Yes ❑ No ❑ Yes ❑ No <br /> Is the vent piping secondarily contained? ® Yes ❑ No M Yes ❑ No M Yes ❑ No ❑ Yes ❑ No <br /> OPW OPW OPW <br /> Overfill Prevention Equipment Manufacturer(s) <br /> 6150 61S0 61S0 <br /> What is the overfill prevention equipment [9 Shuts Off Flow IN Shuts Off Flow $] Shuts Off Flow ❑ Shuts Off Flow <br /> response when activated ? ❑ Restricts Flow ❑Restricts Flow ❑ Restricts Flow ❑ Restricts Flow <br /> (Check all that apply.) ❑ AN Alarm ❑ AN Alarm ❑ AIV Alarm ❑ AN Alarm <br /> Are flow restrictors installed on vent piping ? ❑ Yes M No ❑ Yes M No ❑ Yes M No ❑ Yes ❑ No <br /> At what level in the tank is the overfill prevention 79 . 75 80 . 5 <br /> set to activate? (Inches from bottom of tank.) 81 <br /> What is the percent capacity of the tank at which 94 95 95 <br /> the overfill prevention equipment activates? <br /> Is the overfill prevention in proper operating ® Yes [X Yes [ Yes ❑ Yes <br /> condition to respond when the substance ❑ No ❑ No ❑ No ❑ No <br /> reaches the appropriate level? (Specify in section V.) L (Specify in section V.) (Specify in section V.) (Specify in section V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ® Pass E] Fail M Pass E] Fail L$ Pass El Fail ❑ Pass ElFail <br /> V. COMMENTS <br /> All items marked Fail' must be explained in this section. Any additional comments may also be provided here, <br /> r r7 f11 G <br /> r �W100NM _ � 1 1s i tt <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THISy1NSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations, title 23, division 3, <br /> chapter 16, section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> If the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground storage tank, ICC = Intemational Code Council, AN = Audible and visual <br />