Laserfiche WebLink
UNDERGROUND STORAGE TANK <br />OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br />Type of Action ❑ Installation Inspection ❑ Repair Inspection Z 36 Month Inspection <br />I. FACILITY INFORMATION <br />CERS ID Date of Overfill Prevention Equipment Inspection <br />10181585 4/11/19 <br />Business Name (Same as Facility Name or DBA -Doing Business As) <br />WATERLOO LIQUORS <br />Business Site Address City ZIP Code <br />2512 E WATERLOO RD STOCKTON 95219 <br />II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br />Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone # <br />Edward Stearns (209) 744-0112 <br />Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br />14-1760 Ex. 09/30/2020 8883080 -UT 11/9/2020 <br />Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br />FF- EBW , Phil-Tite & EVR Phase 1 1009893708 Ex 11/29/2020 OPW 104-635 Ex 3-14-2020 <br />Emco 3205 Ex. 11/16/2020 ATG: VR A31048 Ex.8/9/19 Incon 1009893708 11/30/2020 <br />III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br />Inspection Method [E Manufacturer Guidelines (Specify): <br />Used: REMOVE AND INSPECT OPW <br />❑ Industry Code or Engineering Standard (Specify): <br />❑ Engineered Method (Specify): <br />Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages 5 <br />TANK ID: (By tank number, stored product, -etc.) 87 91 DIESEL <br />What is the tank inside diameter? (Inches) 114 96 96 <br />Is the fill piping secondarily contained? ❑ Yes ❑x No ❑ Yes I] No ❑ Yes ❑x No ❑ Yes ❑ No <br />Is the vent piping secondarily contained? ❑ Yes Z No ❑ Yes ❑x No ❑ Yes 0 No ❑ Yes ❑ No <br />Overfill Prevention Equipment Manufacturer(s) OPW OPW OPW <br />61S0 61S0 61S0 <br />What is the overfill prevention equipment response ❑x Shuts Off Flow ❑x Shuts Off Flow Z Shuts Off Flow ❑ Shuts Off Flow <br />when activated? <br />(Check all that apply.) El Restricts Flow El Restricts Flow El Restricts Flow El Restricts Flow <br />❑ A/V Alarm ❑ A/V Alarm ❑ A/V Alarm ❑ AfV Alarm <br />Are flow restrictors installed on vent piping? n Yes ❑ No ❑x Yes ❑ No x❑ Yes ❑ No ❑ Yes ❑ No <br />At what level in the tank is the overfill prevention set <br />to activate? (Inches from bottom of tank.) <br />102.2 <br />86.3 <br />86 <br />What is the percent capacity of the tank at which the <br />94 <br />94 <br />94 <br />overfill prevention equipment activates? <br />Is the overfill prevention in proper operating condition <br />❑x Yes <br />Z Yes <br />Z Yes <br />Eoi <br />to respond when the substance reaches the <br />❑ No (Specify in V.) <br />❑ No (Specify in V.) <br />❑ No (Specify in V.) <br />V) <br />appropriate level? <br />IV. SUMMARY OF INSPECTION RESULTS <br />Overfill Prevention Inspection Results ❑Q Pass El Fail Z Pass El Fail ❑x Pass El ail ❑Pass F1 Fail <br />V. COMMENTS <br />Any items marked "Fail' must be explained in this section. Any additional comments may also be provided here. f7 -_ <br />I1PR 2 <br />VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION � <br />hereby certify that the overfill prevention equipmentwas inspected in accordance v�t1�� ��o�1,�tof,`k2egulatiPt��riTitle 23, <br />Division 3, Chapter 16, Section 2637.2 and all the information contained herein is accura e. 1-1 A '.�r, _ <br />UST Service Technician Signature _ <br />6f ��e 4L <br />If the facility has more components than this form accommodates, additional copies of this page may be attached. <br />'ERS = California Environmental Reporting System, ID = Identfication, UST =Underground Storage Tank, ICC = International Code Council, AN= <br />Audible and Usual <br />