Laserfiche WebLink
t:C>Nlh1UP11CATI01'!S SETUP <br /> IN _TANX SETUP — <br /> PORT SETTINGS : T 1 : REGULAR UNL �J <br /> RECEIVER SETUP : PRODUCT CODE 3 <br /> COMM BOARD i ( RS , 232 <br /> THERMAL COEFF : . 000700 <br /> BAUD RATE 9600 NONE TANK DIAMETER S 92 , 00 <br /> PARITY : EVEN TANK PROFILE 4 PTS <br /> STOP BIT 1 STOP FULL VOL 11730 <br /> DATA LENGTH : 7 DATA 69 . 0 INCH VOL 1 9500 <br /> RS - 232 SECURITY 46 . 0 INCH VOL : 5824 <br /> CODE : DISABLED 23 . 0 INCH VOL : 2161 <br /> COMM BOARD 2 ( FT.MOD ) <br /> BAUD RATE : 2400 FLOAT SIZE : 4 . O IN . <br /> PARITY ODD <br /> STOP BIT i STOP WATER WARNING a 1 . 0 <br /> DATA LENGTH : 7 DATA HIGH WATER LIMIT : 2 . 5 <br /> RS - 232 SECURITY AUTO DIAL TIME SETUP <br /> CODE : DISABLED MAX OR LABEL VOL : 11730 <br /> DIAL TYPE TONE NONE OVERFILL LIMIT 90% <br /> ANSWER Oil 1 RING 10557 <br /> MODEM SETUP STRING: HIGH PRODUCT 95;0 <br /> 11143 <br /> DIAL TONE INTERVAL : 32 DELIVERY LIMIT 8% <br /> 938 <br /> COMM BOARD 3 ( EDIM 7 <br /> RS - 232 SECURITY LOW PRODUCT 500 <br /> CODE DISABLED LEAs: ALARM LIMITS 99 <br /> SUDDEN LOSS LIMIT : 500 <br /> COMM BOARD 5 ( RS - 485 ) TANK TILT 0 . 50 <br /> BAUD RATE : 9600 PROBE OFFSET a — 1 . 39 <br /> PARITY : ODD <br /> STOP BIT i STOP <br /> DATA LENGTH * 7 DATA SIPHON MANIFOLDED TANKS <br /> RS - 232 SECURITY RS - 232 END OF MESSAGE TOO NONE <br /> CODE : DISABLED DISABLED LINE MANIFOLDED TA14KS <br /> T # : NONE <br /> COMM BOARD 6 ( RS - 232 ) AUTO DIAL ALARM SETUP <br /> BAUD RATE 9600 — — — — — — — — — — — — <br /> PARITY ODD LEAK MIN PERIODIC : Or <br /> STOP BIT 1 STOP PRESSURE LINE LEAK ALARM 0 <br /> DATA LENGTH : 7 DATA G 1 : REGULAR MASTER <br /> RS - 232 SECURITY PLLD SHUTDOWN ALARM LEAK MIN ANNUAL O°b <br /> CODE DISABLED JAN 29 . 2009 8 : 05 AM 0 <br /> AUTO TRANSMIT SETTINGS : PERIODIC TEST TYPE <br /> STANDARD <br /> AUTO LEAK ALARM LIMIT <br /> DISABLED ANNUAL TEST FAIL <br /> AUTO HIGH WATER LIMIT ALARM DISABLED <br /> DISABLED <br /> AUTO OVERFILL LIMIT PERIODIC: TEST FAIL <br /> DISABLED - - - - - - PMC ALARM - - - - - - ALARM DISABLED <br /> AUTO LOW PRODUCT Pt°iC SETUP FAIL <br /> DISABLED JAN 29 . 2009 8 : 05 AM GROSS TEST FAIL <br /> AUTO THEFT LIMIT ALARM DISABLED <br /> DISABLED <br /> AUTO DELIVER`: START ANN TEST AVERAGING : OFF <br /> DISABLED PER TEST AVERAGING : OFF <br /> AUTO DELIVERY END <br /> DISABLED TANK TEST NOTIFY : OFF <br /> AUTO EXTERNAL INPUT ON <br /> DISABLED TNK TST SIPHON BREAK : OFF <br /> AUTO EXTERNAL INPUT OFF <br /> DISABLED DELIVERY DELAY 5 MIN <br /> AUTO SENSOR FUEL ALARM PUMP THRESHOLD 10 . 00 <br /> DISABLED <br /> AUTO SENSOR WATER ALARM <br /> DISABLED <br /> AUTO SENSOR OUT ALARM <br /> DISABLED <br /> i <br />