Laserfiche WebLink
STEP 6 : APPLY GREASE TO DROP TUBE <br /> Apply black moly grease to the inside diameter of the <br /> upper drop tube . Make sure coverage is completely <br /> around the tube as shown in Figure 6 . <br /> 1 <br /> Figure 8 <br /> NOTE : Testable inlet tube must have cable port in <br /> line with float . Testable inlet tube bottoms out on <br /> stop , it does not bottom out on inlet flange . See Fig- <br /> ure 8A <br /> Figure 6 <br /> STEP 7 : APPLY GREASE TO POLYPAK SEAL <br /> Ensure that the polypak seal is installed on the inlet <br /> tube with the lip up as shown in Figure 7. Apply black <br /> moly grease to the polypak as shown . Make sure cover- <br /> age is completely around the polypak seal . <br /> Ensure polypak Cable port must be in <br /> lip is up <br /> line with float <br /> Inlet % _- \ <br /> Tube %L Potypak <br /> Figure 8A <br /> Testable Models Only <br /> Apply grease <br /> around polypak SEE PAGE 8 FOR INSTRUCTIONS USING THE 71 SO - <br /> TOOL. <br /> Figure 7 <br /> SEE PAGE 9 FOR INSTRUCTIONS USING THE 71 SO - <br /> STEP 8 : INSTALL INLETTUBE TOOLC . <br /> Insert the inlet tube into the upper tube until the upper <br /> tube seats against the flange on the inlet tube . Ensure SEE PAGE 10 FOR INSTRUCTIONS USING THE 71 SO - <br /> polypak is inserted evenly and stays in inlet tube TOOLCT. <br /> groove . Note: testable 71SO models ending with a "T" require the <br /> 71 SO- TOOLCT or modified 71 SO- TOOL or 71 SO- TOOLC <br /> 7 <br />