My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
1427
>
2300 - Underground Storage Tank Program
>
PR0521942
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2022 9:47:21 AM
Creation date
9/18/2020 3:47:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0521942
PE
2371
FACILITY_ID
FA0014921
FACILITY_NAME
RANCHO SAN MIGUEL MARKET*
STREET_NUMBER
1427
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
16902016
CURRENT_STATUS
01
SITE_LOCATION
1427 S AIRPORT WAY
P_LOCATION
02
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
164
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PREVENTIVE MAINTENANCE Good Valve <br /> Annually, inspect the flapper in the 71 SO to see that it is <br /> open by looking down the drop tube opening (see in - Deflection Shield <br /> spection procedure below) . Test the 71 SO drop tube with Poppet <br /> seals with CARB procedure TP-201 . 1 D . If the drop tube protected <br /> seal passes testing , no further maintenance is required . <br /> If the drop tube fails testing , replace the drop tube seal <br /> with OPW P/ N : H 11931 M for 4" Tubes . Re-test the 71 SO <br /> drop tube with CARB procedure TP-201 . 1 D . The lower <br /> tube o - ring seal OPW P/ N : H14840M can also be re- _ I <br /> placed . If this does not correct the leak the 71 SO needs <br /> to be replaced . <br /> Bad Valve <br /> FOR TESTABLE MODELS ONLY : The socket adaptor Deflection Shield <br /> can be removed and poppet and float movement and with Poppet exposed <br /> function inspected without removing the valve . See <br /> Page 17 for full testing details . If replacement parts are <br /> needed for testable models the following items are <br /> available : OPW P/N 206741 Testable Inlet Tube S/A, <br /> 206740 Socket Adaptor and Cable Assembly, and 61 SOK . <br /> - 0001 Float Kit. <br /> Figure 27 <br /> CAUTION : Do not insert any foreign object into drop <br /> tube if flapper is in the closed position . For exam - Note : Figure 27 shows poppet location with float arm <br /> ple, a tank level measuring stick. This will damage not activated . <br /> the valve and void the Warranty. ALWAYS check <br /> flapper location before "sticking " the tank. If flap- INSP 4 . Inspect the float by lifting upward . The float <br /> per is in the closed position , the tank is either over- should move freely without any binding . See Figure <br /> filled and you need to wait until the liquid level goes <br /> 28s <br /> down or the 71 SO is damaged and needs to be re- <br /> placed . <br /> Open <br /> Inspection Procedure to Ensure Proper Operation <br /> Note : For testable models valve does not need to be <br /> removed from tank. See page 17 for testable instruc- <br /> tions . <br /> INSP 1 . Remove the overfill valve from the tank as de- _ <br /> scribed in step 26 . Float <br /> INSP 2 . Visually inspect the valve for damage . Make <br /> sure no debris or foreign objects are in or on the valve. <br /> INSP 3 . With the float in the normal (down) position , Figure 28 <br /> visually inspect the valve to ensure the poppet is not g <br /> exposed outside the deflection shield . See Figure 27 . INSP 5 . View down the tube to ensure the poppet is <br /> moving into the flow path when lifting the float. See <br /> Figure 29 . <br /> 18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.