My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
610
>
2300 - Underground Storage Tank Program
>
PR0521866
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2020 12:41:21 PM
Creation date
9/21/2020 9:32:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0521866
PE
2371
FACILITY_ID
FA0014852
FACILITY_NAME
RANCHO SAN MIGUEL MARKET*
STREET_NUMBER
610
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
04745039
CURRENT_STATUS
01
SITE_LOCATION
610 S Cherokee Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
289
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Recommended Practices for the Testing and Verification of Spill,Overfill,Leak Detection and Secondary Containment Equipment at UST Facilities <br /> console. If the label is incorrect, contact the 8.3.7 Pass/Fail Criteria. If a sensor triggers an <br /> appropriate person. If no alarm is triggered, alarm when the alarm condition is simulated, and <br /> remove the sensor from the container,check the the sensor is correctly identified on the console,the <br /> connections, allow the liquid to drain from the sensor passes the test. <br /> sensor and immerse it into the liquid again.If the <br /> sensor is replaced,repeat the test procedure. If the sensor does not trigger an alarm when the <br /> alarm condition is simulated, the sensor fails the <br /> 4.Remove the sensor from the test container and test. If the sensor is not correctly identified on the <br /> allow the liquid to drain to clear the alarm. If console, notify the appropriate person to obtain <br /> product is used as the test liquid, follow the authorization to correct the sensor identification. <br /> manufacturer's instructions for cleaning the <br /> sensor before it is replaced. 8.4 Discriminating Sensors. The functionality of dis- <br /> criminating liquid sensors can be determined with the test <br /> 5..positi n. the sensor in the proper location and method described in Section 8.3.6 and substituting the <br /> position. appropriate product for water. <br /> 6.Clear the alarm condition on the console. If <br /> equipped with a printer, print the alarm report <br /> for facility records and indicate that a sensor <br /> functionality test was conducted. <br /> 7.Dispose of product-contaminated water accord- <br /> ing to the guidelines in Section 6.7. <br /> pei.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.