My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2021 4:25:20 PM
Creation date
9/21/2020 11:08:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
126
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PEMP120012 <br /> ATGs are programmed to monitor the product level in warnings or alarms. In the event of any <br /> storage tanks and can be programmed to perform com- such warnings or alarms , notify the appro- <br /> pliance tests that can include 0.2 gph static and dynamic priate person before continuing the test. <br /> ("continuous") leak tests, and 0. 1 gph ("precision") tests . I <br /> ; <br /> Where possible print out the system setup <br /> 8 .2 .1 ATG Functionality Test , and any alarm histories from the console . <br /> Save the printout for facility records or <br /> 8 . 2 . 1. 1 General , The ATG must bepro- make an electronic copy. <br /> grammed using site-specific parameters <br /> for the UST system to ensure proper opera- 8 .2 . 1 . 5 Test Equipment. Test equip- <br /> tion. On dual float systems , the second ment shall include: <br /> float indicates the level of water in the tools for the removal of the ATG probe <br /> tank. and sensors , <br /> 8.2. 1. 2 Purpose. The purpose of this tape measure or gauge stick; <br /> test is to : <br /> • <br /> • determine whether the ATG shows the water-finding paste, <br /> correct product level on the console, 8. 2 . 1. 6 Test Procedure. <br /> • determine whether the ATG shows the 1. Measure the product and water level <br /> correct water level on the console; in the tank and compare to the console <br /> • verify that the water alarm is operating readings to confirm ATG accuracy. If <br /> correctly and provides a warning at the the readings do not agree, contact theappropriate person. <br /> programmed set point. <br /> 2. Remove the ATG probe cap and discon- <br /> WARNING: Water ingress Into tanks con- nect the cable from the ATG, <br /> taining ethanol-blended gasoline may not 3 . Remove the ATG probe from the tank . <br /> be detected using water floats designed Use care to ensure that the floats on the <br /> for non-ethanol-blended gasoline , stem do not catch on the bottom of the <br /> riser during removal. <br /> 8 . 2 . 1.3 Description of Test. The pro- 4. Inspect the probe. The floats must move <br /> cedures in this test are for a probe, properly freely on the stem without binding. If <br /> installed per manufacturer 's instructions, any parts are damaged or missing, con- <br /> equipped with floats having a range inside tact the appropriate person, <br /> the tank that extends from the bottom to 5. Reconnect the probe cable. <br /> the top of the tank. <br /> 6. Set the fuel float in the middle of the <br /> The ATG probe is removed from the tank. probe and verify that it is showing the <br /> The product float and water float positions correct inch reading on the console. <br /> are compared with the console readout. 7. Slowly move the fuel float up the probe <br /> 8. 2 . 1.4 Preparation. Use this test pro- until the high product alarm is triggered <br /> cedure in conjunction with the monitor- on the console. If the system does not <br /> ing system manufacturer's installation and alarm at the pre-set level, contact the <br /> maintenance instructions . appropriate person. <br /> Refer to the tank manufacturers tank <br /> S. Measure the distance from the bot- <br /> chart for the capacity in 1 tom of the probe to the fuel float when <br /> p ty gallons, the diam- <br /> eter and the volume of product that cozre- the float first triggers the high product <br /> alarm. <br /> sponds to the product level . <br /> Verify that the console has no active or 9 . Clear the alarm conditions . , <br /> recurring history of leak detection-related <br /> pei .org <br />