My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4943
>
2300 - Underground Storage Tank Program
>
PR0506488
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:14 PM
Creation date
9/22/2020 2:30:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0506488
PE
2361
FACILITY_ID
FA0007458
FACILITY_NAME
7-ELEVEN INC #32190
STREET_NUMBER
4943
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
CURRENT_STATUS
01
SITE_LOCATION
4943 S HWY 99
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page 1 of 1 <br /> 8 , FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps <br /> Fill Riser Containment Sumps are Present, but were Not Tested <br /> Test Method Developed By : Sump Manufacturer : Industry Standard Professional Engineer <br /> ( Other (Specify) <br /> Test Method Used By : F, Pressure F Vacuum Hydrostatic <br /> ( Other (Specify) <br /> Test Equipment Used: VPLT Equipment Resolution : 0.00001 in. <br /> Fill Containment for Fill Containment for Fill Containment for <br /> Tank T4 RUL - 1 Tank T5 MUL - 1 Tank T6 PUL - 1 <br /> Sump Diameter: 48. 00 in. 48 .00 in. 48 .00 in. in. <br /> Sump Depth : 53 . 00 in. 53 .00 in. 53 .00 in. in. <br /> Height from Tank Top to Top of 19.00 19.00 19.00 <br /> Highest Piping Penetration : <br /> Height from Tank Top to Lowest 15 .00 15.00 15 .00 <br /> Electrical Penetration : <br /> Condition of sump prior to testing: good good good <br /> Portion of Sump Tested 23 23 23 <br /> Sump Material Fiberglass Fiberglass Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15 min 15 min 15 min min <br /> test <br /> Test Start Time: 10:28:00 09:48 :00 09:48:00 <br /> Initial Reading (RI): 0.00000 in. 0.00000 in. 0.00000 in. <br /> Test End Time: 10:58:00 10: 18 :00 10: 18:00 <br /> Final Reading (RF): 400100 in. 400120 in. 400170 in. <br /> Test Duration: 30 min 30 min 30 min <br /> Change in Reading (RF-RI) : -0.00100 in. -0.00120 in. -0.00170 in. <br /> Pass/Fail Threshold or Criteria : +/- 0. 00200 +/- 0.00200 +/- 0.00200 +/- <br /> TestResult: Pass Pass Pass <br /> Is there a sensor in the pump? r Yes r No r Yes r No C* Yes r No r Yes r No <br /> Does the sensor alarm when either !; Yes r Nor NA a Yes r No r NA 1: Yes f-' Nor NA r Yes r Nor NA <br /> product or water is detected? <br /> Was sensor removed for testing? C+ Yes f Nor NA C• Yes r No r NA G Yes f Nor NA C' Yes f" Nor NA <br /> Was sensor properly replaced and r; Yes r No NA r re Yes r No NA r C+ Yes r No NA r r Yes r No NA r <br /> verified functional after testing? <br /> Comments - (include information on repairs made pr•ioj• to testing, and recoi)rnzended folloiv-sip for failed tests) <br /> W0 : 2342949 <br />