Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM (Page ;1 of 6) <br /> This form must be used to document testing and servicing of underground storage tank ( UST) monitoring equipment. A copy <br /> of this form must be provided to the UST owner or operator. The owner or operator must submit a copy of this form to the <br /> local agency regulating the USTs within 30 days of the date of the monitoring system certification . <br /> Li FACILITY INFORMATION <br /> CERS ID Date of Monitoring System Certification <br /> 10165777 9/11 /2019 <br /> Business Name (Same as Facility Name or DBA- Doing Business As . ) Building # <br /> 7- ELEVEN 14113 , MKT 2368 <br /> Business Site Address City : Zip : <br /> 3040 BENJAMIN HOLT DR @ GRIGSBY STOCKTON 95219 <br /> 11 , UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Company Performing the Certification Phone # <br /> TANKNOLOGY INC . (800) 8004633 Ext. <br /> Mailing Address <br /> 11000 N . Mopac Expressway #500 , Austin , TX 78759 <br /> Name of UST Service Technician Performing the Certification (Print as shown on the ICC Certification .) <br /> Jesus Saldivar <br /> Contractor/Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> Class A General Engineering 743160 8361393 6/13/2021 <br /> Monitoring System Training and Certifications (List all applicable certifications . ) Expiration Date <br /> ICC CA UST Service Technician 8361393 06/13/2021 <br /> Veeder Root VR Level 4 B45334 04/28/2021 <br /> VMI TLDT-5000 Tester 3802 11 /20/2019 <br /> 111 . RESULTS OF TESTING/SERVICING <br /> Indicate and attach the following reports if the monitoring equipment is capable of generating either. Y N NA <br /> Monitoring System Set- up Fvl , Alarm History Report <br /> Was any monitoring equipment replaced ? r r r <br /> (If "Yes, "identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below. ) <br /> Was damage , debris , or liquid found inside any secondary containment systems ? r I— <br /> (If "Yes, " describe what was found in section IV below.) <br /> Is all monitoring equipment operational per manufacturer' s specifications ? <br /> (If " No , " describe why in section IV below.) <br /> IV. COMMENTS <br /> If directed to use this section, describe how and when the issues were or will be corrected. <br /> TESTED COMMUNICATION ON ALL THE SITE BUT WAS NOT ABLE TO TEST <br /> COMMUNICATION ON ALL PRODUCT LINES IN UDC' S . . , <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the equipment identified in this document was inspected/serviced in accordance with California Code of <br /> Regulations , title 23 , division 3 , chapter 16 , section 2638 and all information contained herein is true and accurate. Attached <br /> to this certification is information (e . g . , manufacturers ' checklists , monitoring system set-up , alarm history report, etc. ) <br /> necessary to verify that this information and the site plan showing the layout of UST system is complete and accurate . <br /> UST Service Technician Signature <br /> CERS=California Environmental Reporting System , ID= Identification, UST= Underground storage tank, ICC= International Code Council <br />