My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
3040
>
2300 - Underground Storage Tank Program
>
PR0506497
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/28/2020 4:03:21 PM
Creation date
9/22/2020 2:46:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0506497
PE
2351
FACILITY_ID
FA0007461
FACILITY_NAME
7-ELEVEN INC #14113
STREET_NUMBER
3040
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95219
APN
10027018
CURRENT_STATUS
01
SITE_LOCATION
3040 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
106
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM (Page 5 of 6) <br /> XVI. LINE LEAK DETECTOR TESTING <br /> F Check this box if line leak detectors (LLD) are NOT installed . (Do not complete this section. ) Y ; N NA <br /> This section must be completed if LLDs are installed . <br /> Was a leak simulated to verify LLD performance? �- r <br /> (Check all that applyj Simulated leak rate verified : 3 GPH r 1 . 1 GPH r 0 . 2 GPH <br /> Was the testing apparatus properly calibrated ? r r r <br /> For emergency generator tank systems , does the LLD create an audible and visual alarm when a leak is detected ? r r <br /> For mechanical LLDs , does the LLD restrict the flow through the pipe when a leak is detected ? r r r <br /> For electronic LLDs , does the turbine automatically shut off when a leak is detected ? r r <br /> For electronic LLDs , does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected ? (! r <br /> For electronic LLDs , does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? r <br /> For electronic LLDs , have all accessible wiring connections been visually inspected for kinks and breaks? (+� <br /> Were all items on the equipment manufacturer's maintenance checklist completed ? r r <br /> Were all LLDs confirmed operational within regulatory requirements? r r r <br /> For any answer of "N FS above, describe in section X111 how and when these issues were or will be corrected. <br /> XIII. COMMENTS <br /> XIV. VACUUM / PRESSURE/ HYDROSTATIC MONITORING EQUIPMENT TESTING <br /> r Check this box if VPH monitoring is NOT used . (Do not complete this section. ) <br /> This section must be completed if VPH monitoring is used to perform leak detection monitoring . <br /> System Type ( Mark all that apply . ) r Vacuum r Pressure r Hydrostatic <br /> Sensor ID ' Component(s) Monitored by this Sensor Sensor Functionality Interstitial Communication <br /> Test Test <br /> S1 87 PROD . r Pass r Fail r Pass r Fail <br /> S2 87 STP/FILL r Pass r Fail r Pass r Fail <br /> S3 VAPOR/ALL UDC'S r Pass r Fail r Pass r Fail <br /> S4 ALL VENTS r Pass r Fail r Pass r Fail <br /> S5 91 PROD . r Pass r Fail r Pass r Fail <br /> S6 91 FILL/STP r Pass r Fail r Pass r Fail <br /> r Pass r Fail r Pass r Fail <br /> r Pass r Fail r Pass r Fail <br /> r Pass r Fail r Pass r Fail <br /> r Pass r Fail r Pass r Fail <br /> r Pass r Fail r Pass r Fail <br /> r Pass r Fail r Pass r Fail <br /> How was interstitial communication verified ? r Simulated leak at far ends of the interstitial space . r Visual Inspection <br /> r Other Describe the method in section XV below. ) r Gauge <br /> Was the vacuum or pressure restored to operating levels in all interstitial spaces? r Yes r No (Describe the reason in section XV below.) <br /> For any answer of "N " above, describe in section X111 how and when these issues were or will be corrected. <br /> XV. COMMENTS <br /> TESTED COMMUNICATION ON ALL THE SITE BUT WAS NOT ABLE TO TEST <br /> COMMUNICATION ON ALL PRODUCT LINES IN UDC' S . . . <br /> GPH = Gallons per hour, Y = Yes , N = No , NA = Not applicable , VPH = Vacuum/Pressure/ Hydrostatic , ID = Identification <br />
The URL can be used to link to this page
Your browser does not support the video tag.