My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
1111
>
2300 - Underground Storage Tank Program
>
PR0506724
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2020 5:12:39 PM
Creation date
9/22/2020 4:12:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0506724
PE
2361
FACILITY_ID
FA0007594
FACILITY_NAME
WINE COUNTRY STATION/7-ELEVEN
STREET_NUMBER
1111
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04931056
CURRENT_STATUS
01
SITE_LOCATION
1111 E KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SA 'l7bx��l � Environmental Health Department <br /> N3JOAQUIN V_ y�� <br /> —COUNTY— <br /> Underground <br /> OUNTYUnderground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> WINE COUNTRY STATION/7-ELEVEN I 1111 E KETTLEMAN LN, LODI June 26, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> The designated operator failed to document one or more of the following: <br /> On the 10/25/18, 11/16/18, 12/16/18, 1/18/19, 2/13/19, 3/13/19,4/11/19 and 5/10/19designated operator(DO) <br /> inspection report under <br /> -Section III <br /> The DO failed to add a description to all the components marked N/A or N from section VII through XI. <br /> -Section V <br /> The owner/operator failed to provide explanation of follow-up actions that will be taken for the statement provided by <br /> the DO in section III. <br /> -Section VI <br /> The OWNER/OPERATOR failed to provide at least one of the following: name, signature, and date within 48 hours <br /> of receiving the DO report under the ACKNOWLEDGMENT OF COMPLIANCE ISSUES section. <br /> -Section VII <br /> The DO fail to mark yes or No for the question"Has each follow-up action of section III from the previous inspection <br /> been completed appropriately?" <br /> -Section VIII <br /> The designated operator failed to attached documentations as required by this section. <br /> The DO failed to mar YES, NO or N/A under the question"Has the tank tightness testing been completed within <br /> required timeframes?"and"Has the line tightness testing been completed within the required timeframes?" <br /> Furthermore the DO did not conduct an inspection with 30 days of the previous inspection.The DO inspected the <br /> facility on 12/16/18 and on 1/18/19. The DO report was conducted 33 days after the 12/16/18 inspection and not <br /> within 30 days as stated by regulation. <br /> During the designated operator inspection,the designated operator shall review the alarm history for the previous <br /> month, check that each alarm was documented and responded to appropriately, and attach a copy of the alarm <br /> history with documentation taken in response to any alarms to the monthly report. Ensure that designated operators <br /> performing inspections at least once every 30 days at this facility and are including all of the required information on <br /> the reports. <br /> This is a repeat violation, Class II. <br /> 210 CCR 2716(f) DO monthly reports not maintained on site for 12 months or for 36 months(after October 1, 2018). <br /> The June 2018 and June 2019 designated operator monthly inspection reports were not found on site. Designated <br /> operator monthly inspection reports for the previous twelve months shall be retained on site. Locate and ensure that <br /> copies of the previous twelve months of designated operator monthly inspection reports are maintained on site. <br /> Submit copies to the EHD. <br /> This is a repeat violation, Class II. <br /> FA0007594 PRO506724 SCO01 06/26/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 5 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.