My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
9/23/2020 8:40:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
165
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1 ) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection ® 36 Month Inspection <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10156819 2/21 /19 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> Safeway 2600 <br /> Business Site Address City ZIP Code <br /> 1987 W. 11 th St . Tracy 95376 <br /> Ila UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone # <br /> Steven White (408) 971 -2445 <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 485184 8898679 5/10/20 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> 1016243710 / C24135 <br /> B, <br /> III . OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ® Manufacturer Guidelines (Specify) : Veeder Root Cil l 2� 2 10 <br /> Used : <br /> ® Industry Code or Engineering Standard (Specify) : PEI 1200 <br /> fl , iE, _ . t � 2 I ` L H <br /> E] Engineered Method (Specify): r , ,� t� I <br /> Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages <br /> TANK ID : (By tank number, stored product, etc.) T1 Regular T2 - Premium T3 - Diesel <br /> What is the tank inside diameter? (Inches) 119 . 75" 119 . 75" 119 . 75" <br /> Is the fill piping secondarily contained? ❑✓ Yes ❑ No © Yes ❑ No © Yes ❑ No ❑ Yes ❑ No <br /> Is the vent piping secondarily contained? ® Yes ❑ No © Yes ❑ No © Yes ❑ No ❑ Yes ❑ No <br /> Overfill Prevention Equipment Manufacturer(s) Ball Floats / Modem Welding Ball Floats / Modem Welding Ball Floats / Modem Welding <br /> Veeder Root Veeder Root Veeder Root <br /> What is the overfill prevention equipment response ❑ Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow <br /> when activated? <br /> (Check all that apply.) ® Restricts Flow ® Restricts Flow ® Restricts Flow E] Restricts Flow <br /> ® AN Alarm ® AN Alarm ® A/V Alarm ❑ A/V Alarm <br /> Are flow restrictors installed on vent piping? (z1 Yes ❑ No ✓❑ Yes ❑ No ® Yes ❑ No ❑ Yes ❑ No <br /> At what level in the tank is the overfill prevention set <br /> to activate? (inches from bottom of tank.) 113" 114" 114" <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 97 . 7% 98. 2% 98 . 2% <br /> Is the overfill prevention in proper operating condition ❑ Yes ❑ Yes El Yes ❑ Yes <br /> to respond when the substance reaches the <br /> appropriate level? ® No (Specify in V) ® No (Specify in V.) ® No (Specify in V.) ❑ No (Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results I I ❑ Pass ® Fail ❑ Pass ® Fail ❑ Pass ® Fail ❑ Pass ❑ Fail <br /> V, COMMENTS <br /> Any items marked "Fail" must be explained in this section. Any additional comments may also be provided here. <br /> T1 , T21 T3 are all too high (>95%) <br /> Tested the AN with probe and all tests at 90% alarm . <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> 1 hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations , Title 23 , <br /> Division 3 , Chapter 16, Section 2637 . 2 and all the information contained herein is accurate. <br /> UST Service Technician Signature ' <br /> t <br /> If the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = International Code Council, AN = Audible and Visual <br />
The URL can be used to link to this page
Your browser does not support the video tag.