My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15237
>
2300 - Underground Storage Tank Program
>
PR0517272
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2022 12:11:11 PM
Creation date
9/23/2020 11:35:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0517272
PE
2361
FACILITY_ID
FA0012979
FACILITY_NAME
FLYING J TRAVEL PLAZA #617
STREET_NUMBER
15237
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
02519014
CURRENT_STATUS
01
SITE_LOCATION
15237 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
161
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page 8 of 13 <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By : ❑ Tank Manufacturer K Industry Standard ❑ Professional Engineer <br /> ❑ Other (Spec) <br /> Test Method Used : ❑ Pressure A Vacuum ❑ Hydrostatic <br /> ❑ Other (Spec) <br /> Test Equipment Used : Analog Vacuum Gauge Equipment Resolution: +/-0 . 25 <br /> SEE Tank # 1 Tank # 2 Tank # 3 Tank # 4 <br /> Is Tank Exempt From Testing? ' X Yes ❑ No K Yes ❑ No ® Yes ❑ No N Yes ❑ No <br /> Tank Capacity : 20 , 000 Gallons 20 , 000 Gallons 20 , 000 Gallons 20 , 000 Gallons <br /> Tank Material : Fiberglass Fiberglass Fiberglass Fiberglass <br /> Tank Manufacturer: Xerxes Xerxes Xerxes Xerxes <br /> Product Stored : 87 Unleaded 87 Unleaded 87 Unleaded 87 Unleaded <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test : <br /> Test Start Time : <br /> Initial Reading (RI) : <br /> Test End Time : <br /> Final Reading (RF) : <br /> Test Duration : <br /> Change in Reading (RF-RI) : <br /> Pass/Fail Threshold or Criteria : <br /> Test Result. ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> Was sensor removed for testing? ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br /> Was sensor properly replaced and ❑ yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br /> verified functional after testing? <br /> Comments — (include information on repairs made prior* to testing, and z•ecomnzended follow-up for failed tests) <br /> * All Tanks Are Liquid Fill <br /> ' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br /> testing. {California Code of Regulations, Title 23 , Section 2637(a) (6) } <br />
The URL can be used to link to this page
Your browser does not support the video tag.