My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2360
>
2300 - Underground Storage Tank Program
>
PR0507204
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/29/2024 12:37:42 PM
Creation date
9/23/2020 12:57:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0507204
PE
2361
FACILITY_ID
FA0007735
FACILITY_NAME
7-ELEVEN INC #32262
STREET_NUMBER
2360
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
23819001
CURRENT_STATUS
01
SITE_LOCATION
2360 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATIONFORM ( Page', I of 6) <br /> This form must be used to document testing and servicing of underground storage tank ( UST) monitoring equipment. A copy <br /> of this form must be provided to the UST owner or operator. The owner or operator must submit a copy of this form to the <br /> local agency regulating the USTs within 30 days of the date of the monitoring system certification . <br /> Is FACILITY INFORMATION <br /> CERS ID Date of Monitoring System Certification <br /> 10166021 3/1 /2019 <br /> Business Name (Same as Facility Name or DBA-Doing Business As . ) Building # <br /> 7-ELEVEN #32262 , MKT 2368 (N-3940A <br /> Business Site Address City : Zip : <br /> 2360 W GRANTLINE k205 OFF RAMP TRACY 95376 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Company Performing the Certification Phone # <br /> TANKNOLOGY INC . (800) 800-4633 Ext. <br /> Mailing Address <br /> 11000 N . Mopac Expressway #500 , Austin , TX 78759 <br /> Name of UST Service Technician Performing the Certification (Print as shown on the ICC Certification .) <br /> Steve Willems <br /> Contractor/Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> Class A General Engineering 743160 8234559 1 5/22/2020 <br /> Monitoring System Training and Certifications List all applicable certifications . ) Expiration Date <br /> Tanknology Certification Level III ATG Operability Training Certification Exam 114535 11 /07/2019 <br /> ICC CA UST Service Technician 8234559 05/22/2020 <br /> Veeder Root VR Level 4 836743 07/02/2020 <br /> VMI TLDT-5000 Tester 1931 11 /26/2020 <br /> III. RESULTS OF TESTING/SERVICING <br /> Indicate and attach the following reports if the monitoring equipment is capable of generating either. Y N NA ' <br /> F Monitoring System Set- up Alarm History Report <br /> Was any monitoring equipment replaced? r I✓ r <br /> (If "Yes, "identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below) <br /> Was damage , debris , or liquid found inside any secondary containment systems? I— <br /> (If "Yes, " describe what was found in section IV below.) <br /> Is all monitoring equipment operational per manufacturer' s specifications? �— <br /> (if " No , " describe why in section IV below. ) <br /> IV. COMMENTS <br /> If directed to use this section, describe how and when the issues were or will be corrected. <br /> t <br /> removed 2 gals of liquid from 87 , 89 . and 91 fill sumps <br /> i <br /> i <br /> i <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> 1 hereby certify that the equipment identified in this document was inspected/serviced in accordance with California Code of <br /> Regulations , title 23 , division 3 , chapter 16 , section 2638 and all information contained herein is true and accurate . Attached <br /> to this certification is information (e. g . , manufacturers' checklists , monitoring system set-up, alarm history report, etc. ) <br /> necessary to verify that this information and the site plan showing the layout of UST system is complete and accurate. <br /> UST Service Technician Signature <br /> CERS=California Environmental Reporting System , ID=Identification , UST=Underground storage tank, ICC= International Code Council <br /> r <br />
The URL can be used to link to this page
Your browser does not support the video tag.