Site Plan Keynotes "
<br /> GARBAGE AND RECYCLING AREA, SEE SHEET 0APD
<br /> A1.9
<br /> EAST M O RADA LANE MECHANICALLY OPERATED ELECTRIC ENTRY
<br /> GATE W/CALL DEVICE. SEE SHEET A1.8 American Property Development,Inc.
<br /> 110 11 EXISTING SITE ACCESS EASEMENT
<br /> t venue suite 55
<br /> _ _ _ �3 FIRE CONTROL ROOM @ BUILDING, TYP. Bellevue,WA 98004
<br /> o I
<br /> 4 COLORED CONCRETE WALK, 4" THICK,
<br /> 6'HIGHPRE-CA ST ALONG MORADA, I "BROOM FINISH"
<br /> MATCH SOUND WALL DESIGN
<br /> a'MI WALK WIDTHS 1flPOOL AND SPA AREA SEE A1.3
<br /> 28 E6 LEASING OFFICE DIRECTION SIGN, SEE 9/A10.1
<br /> I I - - -
<br /> 30' ❑7
<br /> \\ 1-6" TYPICAL CARPORT SEE A1.7
<br /> POWDER COATED METAL FENCING AT
<br /> XISTI�JG RIVE E -- O G E O G 39 8 POOL AREA . SEE DETAIL 12/A1.5
<br /> WALL D
<br /> 2A 2A WALL ALONG General Notes [flPEDESTRIAN ACCESS GATE, SEE 5b/A1.5
<br /> F EAST SIDE 4 FEET WIDE FIRE GATE WITH LATCH BOLT &
<br /> 1 SIDESLOPE AT ALL WALKS PER CIVIL DWGS. 2% MAX. 10
<br /> 2 2s 2 6" HIGH EXTRUDED CURB AT LANDSCAPE PADLOCK BOX, 1 LOCATION. SEE DTL.
<br /> \ ® - ---N ISLANDS, 15/A1.5 5/A1.6
<br /> \\� \❑,o � - -- -- - - 26= 3 FULL SIZE PARKING SPACES AT 9'-0" X 19'-0" MIN. 11 CONCRETE WALK. 4" THICK WITH CONTROL ��D ARch,
<br /> \\\ 23 AND EXPANSION JOINTS, 4' MIN. WIDTH TYP.
<br /> \\ \ 6' 40 b. 20 4 COMPACT SIZE PARKING SPACES AT 8'-0" X 16-0" 12 GARAGE, SEE SHEET A1.4a C)
<br /> MIN.
<br /> 47 13 ADA VAN ACCESSIBLE PARKING STALL J FATAH BOUALAMALLAH
<br /> \� \ 6'4Curb o I 5 ADA SIZE PARKING SPACES AT 9'-0"X19'-0" WITH 5'-0" SEE SHEET A1.7 FOR HEIGHT CLEARANCE -37782
<br /> MIN. AISLE BETWEEN. VAN - 9' x 19' WITH 8' AISLE 14 PRE-MANUFACTURED DOG WASH STATION
<br /> 6 ALL GATES SHALL BE EQUIPPED WITH ACCESSIBLE ALUMINUM 12' TALL FLAGPOLES, TYP. 2 RENEWAL DATE
<br /> MEANS OF EMERGENCY ENTRY (KNOX BOX, KS-2) 15 PLACES. SEE A1.9 -9�� 03/31/21 0��
<br /> 7 INSTALL EXTRUDED CURBS ON SITE UNLESS 16 SPEED LIMIT SIGN (2), SEE A10.1 OF cp,
<br /> E 8 \ c OTHERWISE NOTED
<br /> G ® c 17 FUTURE RESIDENT SIGN (2), SEE A10.1
<br /> \ 8 WHEELSTOPS PROVIDED AT ALL SPACES MAINTAIN
<br /> c INTEGRAL COLORED 5" THICK CONCRETE (@ COPYRIGHT © 2005, ALL RIGHTS RESERVED
<br /> 2'-0" SETBACK FROM SIDEWALKS, 20/A1.5 18
<br /> 2A 22 \ G6 PAITTERN AT DIRIVENG SA AISLE. REINFORCEWITHTH 9 ACCESS IS REQUIRED TO WITHIN 150 FEET OF ANY SUBMITTAL/REVISIONS
<br /> PORTION OF ALL BUILDINGS FROM THE FIRE #3 BARS @ 24 O.C. EACH WAY # DATE DESCRIPTION
<br /> DEPARTMENT ACCESS ROAD. ACCESS CANNOT
<br /> 19\\\ FIRE HYDRANT LOCATIONS. SEE CIVIL DWGS.
<br /> 2 �-z6-1a For Bid
<br /> CROSS RETENTION, LANDSCAPE, WALLS OR PASS 8-15-18 For Permit\ 6 �� 6 1 G) UNDER COVERED WALKWAYS 20 TRASH COMPACTOR, SEE A1.6
<br /> I o Typical
<br /> III " carports G7 10 CBC TABLE 602: FOOTNOTE H, A CARPORT DOGGIE BAG STATION, SEE 15/A1.9 3 11-18-18 Addenda3
<br /> 21
<br /> K EXTERIOR WALL SHALL NOT BE REQUIRED TO HAVE 22 BIO-RETENTION AREAS. SEE CIVIL FOR s 2-13-19 Addenda
<br /> iA FIRE-RESISTANCE RATING WHERE THE FIRE DETAILS 3-7-19 Addenda?
<br /> G` SEPARATION DISTANCE IS 5 FEET OR GREATER 23 RECYCLE BINS
<br /> I I 12 / 26 °II 24 9-18-19 Addenda 12 2A G6 c 1 PRECCASTPCON RETEEF NCE,AS E 12 18/A1.5.
<br /> '° G, Legend And Symbols 25 MINIMUM SURFACE WEIGHT OF 3.5-4 LBS/FT
<br /> 1 ® O G I 26 SECURITY CAMERA LOCATIONS. COORDINATE
<br /> E I WITH VENDOR. SEE A1.9
<br /> / INDICATES BUILDING NAME FOR 27 CROSSWALK. SEE 17/A1.5 AND CIVIL DWGS
<br /> EXISTING o ,9 ADDRESSING 28 POWDER COATED METAL FENCE, SEE 12/A1.5
<br /> EXISTING DRIVE 15 21 n1.5
<br /> 13 INDICATES APARTMENT BUILDING
<br /> APARTMEN S I A0
<br /> 2.8 G 8 I A'.5 B-4 TYPE PARKING WHEELSTOP, 20/A1.5
<br /> 28 0 3 G 8888 1329I 0
<br /> 43 I` 30 2 BENCHES, 2 FLOWER POTS AND 2�• m mm GS e j > G \ e INDICATES CARPORT TRASH CANS AT ENTRY (SEE SPECS.)
<br /> ��O`er Qpn m 1 L ' 31 PROJECT SIGN, SEE 17/A1.6
<br /> • O m FITNESS
<br /> • •I m 26 CENTER 1 32 GAS BARBECUE
<br /> RECREATION m U INDICATES GARAGES
<br /> BUILDING m m 1 • n/ G1 33 MECHANICAL EQUIP. SCREEN WALL. SEE VJ
<br /> 6 --- 4 � m 13 I " L�L 4A/A1.3, SIMILAR, 4' TALL r I•'�
<br /> \ m INDICATES TRANSFORMER WITH PURVEYOR V
<br /> � 6'Curb/
<br /> 9 88 I G4 FT1 STANDARD CONCRETE PAD 34 EMERGENCY GATE-MATCH POST AND
<br /> \ 2-CAMERAS 26 • 0 m 'm p DESIGN SHOWN ON 11/A1.8. PROVIDE z
<br /> A,8
<br /> 14 6' 6 I } CHAIN AND PADLOCK
<br /> ® 37
<br /> 0138 46 I I � Q 35 EXISTING EMERGENCY GATE U)
<br /> � I I
<br /> 0
<br /> � > ° POLE or BUILDING MOUNTED SECURITY CAMERA ' w
<br /> [Y POLE ELECTRICAL DRAWINGS. v,
<br /> 'Curb/C31 22 j - PROPERTY SETBACKS 36 CONTRACTOR TO SUPPLY CONCRETE PAD
<br /> 2
<br /> 19 OE- O F _ � FDC. SEE CIVIL FOR LOCATIONS 37 BIKE RACK. SEE 17/A1.4 0
<br /> I 4' G
<br /> TYPICAL 1 I p I 38 LANDSCAPING. SEE L&I DWGS. NO OVER n/
<br /> HYDRANTD . SEE CIVIL FOR 11....x`
<br /> 2A I FH LOCATIONS 6' HIGH PLANTS WITHIN 20' OF THE BLDG
<br /> 29 D 00 PERIMETER UNLESS WITH ROOT BARRIER. U
<br /> 16 18 $' 26 _ 1s I 0 39 CONCRETE SOUND WALL WITH MIN.
<br /> _ N A,5 0 SURFACE WEIGHT OF 3.5 TO 4 LBS. SEE U) Q
<br /> TYPICAL
<br /> ,s 0 12/A1.5
<br /> SIGN INDICATES SIGNAGE. A DESIGN 40 EMERGENCY GATE & EXIT ONLY, SEE A1.8 Q
<br /> 1 -
<br /> " REVIEW IS REQUIRED. SEPARATE
<br /> SIGNAGE PERMIT SUBMITTAL FOR 41 SITE BENCH, SEE 15/A1.9 Z 0
<br /> LL
<br /> CAR WASH AREA. PROVIDE 4"
<br /> G G a -� THIS PROJECT WILL FOLLOW 42 CONCRETE SLAB WITH THICKENED EDGE, � �
<br /> F BUILDING FIRE CONTROL ROOM J
<br /> I I I
<br /> 1 w..ERs°Ak,EA I E BUILDING ELECTRICAL ROOM DRAIN AND HOSE BIBB 5 U
<br /> / 1 1 7 1 1 I G BUILDING GAS METER STACK (EXTERIOR) 43 TRELLIS AT POOL & SPA AREA. SEE A1.9 0 L
<br /> ( ) 44 CMU WALL, SEE DETAIL 12/A1.5 2 z
<br /> / I I I I C COMPACT SPACE ALL OTHERS LARGE I-
<br /> I 1 21 I I I SG SITE GATE 45 POOL EQUIPMENT SUPPLY BOX, SEE w u- 0
<br /> RG RECREATION BUILDING GATE SPECS. J
<br /> 2 2A O 3 2A I I 6' HIGH BLACK POWDER BOOSTER PUMP. SEE A2.1 AND ~ ^Uj �^ U
<br /> I I 46 = L.L 0
<br /> / \/ I, COATED FENCE CIVIL-MECHANICAL. SEE 4A/A1.3, 4' w
<br /> I, I I TALL CMU WALL 0 U)
<br /> ACCESSIBLE PARKING
<br /> 22 I I I OR DESIGNATION UNIT 47 CMU ENCLOSURE, SEE 9/A1.6 �
<br /> �2O1IDOG WASTE DISPOSAL STATION HOUR WALL @CARPORT, SEE 20/A10.8
<br /> / 23 26 I E n
<br /> 49 REMOVE ANY EXISTING PALM TREE(S)
<br /> 4, E
<br /> DAND SIDEWALK THAT INTERFERES WITH
<br /> p A
<br /> 36 E 2, E 5' LEA SITE BENCH GATE.
<br /> I I
<br /> �- K 71
<br /> I11 12I G PARKING LOT LIGHT POLE
<br /> s' WA C==E
<br /> 2s
<br /> I
<br /> DECORATIVE 12' POLE LIGHT
<br /> I I ,e,FB
<br /> I I
<br /> 26'
<br /> V-4"
<br /> G3
<br /> I I
<br /> O (DTYPICAL I 0 4' 16" 24"
<br /> `BUILDING
<br /> / TYPE I I z
<br /> 2' 8'
<br /> 42 3 3 ite Plan
<br /> vVI (1:96)
<br /> SCV-101" Q
<br /> "
<br /> _ 60, J
<br /> G G 34 NORTH
<br /> mil
<br /> LLI
<br /> EMER $�!CY ACCESS zo > I EMERGENCY ACCESS
<br /> N N y
<br /> G2 3 F:
<br /> J N U)
<br /> EXIST RESIDENTIAL RLBY
<br /> R- 1 SOUTH SIDE DAF DRAAF
<br /> 7'H I G
<br /> 0 30' 120' 180' SHEET NUMBER
<br /> 15' 60'
<br /> SCALE 1" = 60' (1 : 720) Al
<br /> ■
<br /> O:\PROJECTS\STOCKTON_CA PHASE 2\01-Architectural\AutoCAD\2019 re-design\A01_01.dwg,8/9/2019 3:34:45 PM
<br />
|