Laserfiche WebLink
GENERAL REINFORCEMENT �o <br /> a 00 <br /> - III- 1. THE SITE CONDITIONS HAVE NOT BEEN 15. REINFORCEMENT SHOULD BE PLACED IN <br /> INSPECTED BY LENEHAN ENGINEERING.IF SITE ACCORDANCE WITH CBC 1908.4 AND ACI 318 CH.25 O 0 O <br /> -III- BEGIN ADDED VERT.BARS 3 CONDITIONS VARY FROM THAT PROVIDED IN AND BE ASTM A615 GRADE 40 OR BETTER FOR#3 <br /> STANDARD REINF. -III FEET BELOW TOP OF BOND THIS PLAN,LENEHAN ENGINEERING SHOULD BE AND#4 BARS.SPLICES ARE TO BE LAPPED A tr) b,10 bJ0 <br /> GRID #4@12"O.C.E.W. 111- BEAM. CONTACTED. MINIMUM OF 40 BAR DIAMETERS.CONTACT 1r) d- r- r. <br /> i IF <br /> 2. THIS STANDARD PLAN HAS BEEN DEVELOPED SPLICING MAY BE USED PROVIDED SPLICED BARS d- <br /> RADIUS STD.FLOOR BASED ON THE 2019 CBC,ASCE 7,AND ACI 318. ARE IN THE SAME PLANE AND PARALLEL TO THE <br /> PER TABLE 1 REINFORCEMENT: DIRECTION OF THE GUNITE SHOOTING. U I� <br /> 3. COPING:EXPANSION JOINT OF MASTIC OR OTHER <br /> ACTUAL DIG #3@12"O.C.E.W. SEPARATOR SHOULD BE PLACED BETWEEN 16. ALL BENDS ARE TO BE SHARP. O N <br /> ADDED VERT.BARS PER <br /> - <br /> LINE MAY VARY _ _ H,POOL WALL HEIGHT. TABLE L CONTINUE 24" CONCRETE DECKS AND COPING AND SHOULD 17. 1#4 BAR MAY BE REPLACED WITH(2)#3 BARS a O <br /> PLACE REINF.3" - EXTEND THE FULL DEPTH OF THE DECK. PROVIDED A 2.5-INCH MINIMUM CLEARANCE IS <br /> 7'MAX PER TABLES 1�2 MIN INTO FLOOR <br /> FROM SOIL i_ 4. ALL ELECTRICAL IS TO BE ELECTRICALLY MAINTAINED. O <br /> I- o D,GUNITE COVER,PER 3"CLEAR COVER TO SOIL GROUNDED IN ACCORDANCE WITH THE 2016 18. AREAS WHERE SOIL SUPPORT HAS BEEN V-4 <br /> 4� <br /> ADD#4@12"O.C.BY 6'LONG AT TABLE 2.TO BE CHANGED CALIFORNIA ELECTRICAL CODE ARTICLE 680. TEMPORARILY REMOVED,LE.RAMP r� <br /> BEGINNING AND END OF UNIFORMLY WITH DEPTH = (IF APPLICABLE MAY CONSIST EXCAVATIONS,SHOULD HAVE#3 BARS AT 6 N <br /> FLOOR TRANSITION 5. WALL DRAINAGE ) <br /> _ OF A 12-INCH GRAVEL DRAIN WRAPPED IN A INCHES ON CENTER,VERTICAL AND 0 <br /> SEE NOTE 12 FOR SOIL FILTER FABRIC OR A DRAINAGE COMPOSITE. HORIZONTAL. <br /> CONDITIONS WHERE 4-INCH RADIUS DRAIN BOTH OPTIONS TO A 3"0 PERFORATED PIPE. 19. 3 INCH MINIMUM CLEARANCE IS REQUIRED <br /> GRAVEL DRAIN IS REQUIRED PER TABLE 1 1= DISCHARGE TO EXISTING DRAINAGE SYSTEM. BETWEEN REINFORCEMENT AND SOIL AND A 2 <br /> 6"MIN STANDARD6. CONTRACTOR OR OWNER SHALL VERIFY ALL INCH CLEARANCE BETWEEN REINFORCEMENT <br /> FLOOR THICKNESS - � FIRM NATIVE SOIL FIELD CONDITIONS AND DIMENSIONS PRIOR TO AND WATER OR EXPOSED TO AIR. <br /> o - CONSTRUCTION. 20. GUNITE SHALL BE PLACED AGAINST r n <br /> SEE DETAIL 5 FOR PRESSURE RELIEF VALVE O 7. INTERIOR SURFACE OF POOL SHALL BE COATED <br /> UNDISTURBED NATIVE SOIL OR COMPACTED u <br /> o III - - WITH A WATER-TIGHT SURFACE. ENGINEERED FILL. <br /> LOCATE IN DEEPEST PORTION OF POOL _ / Ei <br /> 8. CONSTRUCTION SHALL COMPLY WITH 2016 V^` <br /> CALIFORNIA BUILDING CODE,2019 CALIFORNIA SHOTCRETE <br /> 1 TYPICAL POOL SECTION PLUMBING CODE,2019 CALIFORNIA ENERGY CODE, <br /> 21. CEMENT SHALL CONFORM TO CBC SECTION 1903.1, <br /> 2019 BUILDING EFFICIENCY STANDARDS,2019 ACI 318 CH.19,ASTM C 150 <br /> CALIFORNIA GREEN BUILDING STANDARDS,2019 . <br /> 12" 6" DECK SLAB CALIFORNIA MECHANICAL CODE,2019 22. GUNITE IS A COMMON TERM THAT REFERS TO W <br /> EXPANSION JOINT #4 BARS E.W.X 24" CALIFORNIA E <br /> ORDINANCES.LECTRICAL CODE,AND LOCAL THE SHOTCRETE DRY MIX PROCESS AND IS <br /> ACCEPTABLE TO USE WITH THIS PLAN. <br /> SEE NOTE 3 9. CONTINUOUS SHOTCRETE INSPECTIONS SHALL 23. GUNITE CEMENT TO AGGREGATE PROPORTIONS 7 <br /> 24 DECK SLAB2 _ BE PERFORMED BY A SPECIAL INSPECTOR AS SHOULD NOT BE LESS THAN 1 TO 5 AND SHOULD L- <br /> MAX 6'1 . . 3" - REQUIRED BY BUILDING AGENCY. CONFORM TO CBC 1908 AND ACI 506. <br /> COPING TILE 24. MINIMUM CONCRETE 28-DAY COMPRESSIVE r n <br /> 11 <br /> SOILS STRENGTH IS 2,500 PSI,TYPE V CEMENT,AND A u <br /> 8" (2)#4 BARS 6 O WATER TO CEMENT RATIO OF 0.45. wz <br /> 6 10. LATERAL EARTH PRESSURE:60 PCF(EQUIVALENT 25. MINIMUM WALL THICKNESS IS 7INCHES. <br /> MIN(2)"Z" - 1 FLUID PRESSURE). <br /> 26. EXPOSED POOL AND SPA WALLS WITH PLUMBING <br /> (3)#4 MIN BARS WITH - AT SKIMMER USE 11. POOL SHOULD BE FOUNDED ON FIRM NATIVE MUST BE AT LEAST 10 INCHES WIDE WITH DOUBLE <br /> REINF.PER 1/SP1.0 12"LAP I- <br /> WALL THICK.AND (2)#4 BARS(MIN) = SOILS OR ENGINEERED FILL WITH WRITTEN <br /> O - ( CAGE REINFORCEMENT. REINFORCEMENT CAGE <br /> 8'LONG APPROVAL FROM SOILS ENGINEER)WITH A SHALL CONSIST OF VR.:#3@12"O.C.ON BOTH <br /> #4 DIAGONAL FACES,H.R.:#3@6 <br /> MINIMUM BEARING CAPACITY OF 1,500 PSF. I I <br /> "O.C.ON EXPOSED EXTERIOR <br /> BARS X 24" 12. A HYDROSTATIC RELIEF VALVE IS REQUIRED TO FACE,#3@12"O.C.ON INTERIOR FACE.PLUMBING <br /> • WALL THICKNESS PREVENT BELOW POOL UPLIFT PRESSURES.IF SHALL BE KEPT A MINIMUM OF 1.5 INCHES FROM <br /> AND REINF.PER 1/SP1.0 SEEPAGE IS OBSERVED IN AN OPEN EXCAVATION, ANY HORIZONTAL REINFORCEMENT. <br /> A GRAVEL DRAIN IS REQUIRED BELOW THE POOL 27 KEEP GUNITE DAMP CONTINUOUSLY FOR 14 DAYS. <br /> FLOOR TO ALLOW THE DISSIPATION OF <br /> HYDROSTATIC PRESSURES. <br /> SPECIAL INSPECTIONS <br /> 2 COPING DETAL 3 SKIMMER 4 LIGHT NICHE 13. KEEP ALL EXPANSIVE SOILS IN A MOIST <br /> CONDITION PRIOR TO THE PLACEMENT OF 28. SHOTCRETE TEST PANEL PER ACI 506 SECTION 6.4. <br /> 2 GUNITE. <br /> 14. DECK DETAILS SHOW MINIMUM CONSTRUCTION <br /> AND DO NOT DEMONSTRATE A SYSTEM THAT <br /> 1 111111111 WILL RESIST HEAVING DUE TO SOIL EXPANSION. <br /> III III i <br /> REMOVABLE CAP OR STAIR REINF. III 11111 (/� <br /> STD. PLUG.SEE NOTE 12 #3@12"O.C.E.W. <br /> FLOOR FOR CONDITIONS <br /> W/12"MIN LAP SPLICES Ir 7:1 <br /> REINF. STD.FLOOR U a Chi <br /> 4'MAX HEIGHT '� p <br /> THICKNESS #4 BARS 48" <br /> LENGTH DIAGONAL O <br /> TABLE 1-ADDED VERTICAL BARS U <br /> WALL REINF. TO STANDARD GRID TABLE 2-WALL THICKNESS w p O <br /> 12" SLOPE SLAB #4@12"O.C.E.W. (/� o <br /> WALL HEIGHT RADIUS EFP=60 PCF WALL HEIGHT EFP=60 PCF M <br /> O o O O TO DRAIN MAIN DRAIN j, (FT.) (FT.) ADDED BARS O <br /> (FT) "(DD,GUNITE " <br /> COVER(IN.) 1 <br /> 4 1 STD.GRID <br /> 5 2 STD.GRID 4 4 <br /> 18"SQUARE GRAVEL = I 1 , 4 <br /> AROUND RELIEF VALVE _ <br /> 6 3 STD.GRID <br /> 11„-,1 d... 1 6 <br /> -; TYP.FLOOR = - 7 4 (1)#4 <br /> -III-n -I 1-1 III II II I_ THICK.7° 'I 111 II I it 5 <br /> FIRM NATIVE SOIL TABLE NOTES: <br /> 1. EFP REFERS TO EQUIVALENT FLUID PRESSURE. <br /> 2. TOTAL WALL THICKNESS IS D,GUNITE COVER(TABLE 2)PLUS 3 INCHES CLEAR COVER TO SOIL. v <br /> m c <br /> o N <br /> 5 PRESSURE RELIEF 6 MAIN DRAIN 7 TYPICAL STAIRS U <br /> 2 LIFT ANCHOR �NG1 R <br /> - ASSEMBLY �Q� �N NN <br /> III= - POOL WALL EDGE <br /> •...................... - =111=1I r 00 N = Q z <br /> AH-I5 Q AS REQUIRED PER ADA LIFT w <br /> MANUFACTURER'S o 6 w <br /> GALVANIZED#4 BAR PLAN VIEW STANDARD REINF. 1 I 1 I1 1' 3'-6" a d a <br /> GRID #4@12"O.C.E.W. III E RECOMMENDATIONS <br /> 48"LENGTH 111 Q O� 5 z <br /> CENTERED OVER MIDDLE <br /> OF EACH ST BARS <br /> Y-6` o O <br /> 1 WALL FOUNDATION PLAN VIEW ,� N <br /> HEIGHT ADDED VERT.BARS PER Q O <br /> - <br /> MAX 7 FT TABLE L CONTINUE 24" <br /> _ v_ MIN INTO FLOOR FOUNDATION REINF.#4 @ P.-I bCrq �* U <br /> PER TABLE I -- <br /> • = = - D,GUNITE COVER,PER 10"O.C.E.W.TOP&BOTTOM ,� :4 <br /> -111-� = TABLE 2.TO BE CHANGED CONTINUE TYPICAL ;-4 cu <br /> Qf p^ <br /> III-I UNIFORMLY WITH DEPTH DECK THICKNESS& LIFT ANCHOR 1/2"EXPANSION p <br /> 5' REINF.BY OTHERS ASSEMBLY2 JOINT <br /> Z <br /> III Z <br /> � P-a <br /> LR V - � � _ <br /> � VERT.REINF.PER TABLE 1 PER TABLE 1 - MIN -�I i�I�MIN zr� <br /> 7 <br /> WALL THICKNESS PER TABLE I - III a d w <br /> FIRM NATIVE SOIL 44 <br /> TYPICAL POOL 0 <br /> 1 6 - - - �� �IIIiII I1 3, �� <br /> 6SQ X1 `� <br /> 1 WALL� � <br /> TYP.FLOOR = - _ <br /> SECTION ELEVATION THICK.7" TYPICAL FLOOR REINF. SECTION VIEW E O <br /> #4@12"O.C.E.W. G_ ~ <br /> 0 _ <br /> 8 RECESSED STAIRS 9 TYPICAL POOL WALL 10 ADA LIFT FOUNDATION U W <br /> U <br />