Laserfiche WebLink
REVISIONS <br /> GENERAL NOTES NO. DESCRIPTION DATE <br /> 1. REFER TO SHEET E1 FOR DEVICE AND SYMBOL SCHEDULES. <br /> 2. PROVIDE COPPER EQUIPMENT GROUNDING CONDUCTOR, SIZED PER <br /> 1 2 3 4 4.2 5 6 7 8 8.1 9 10 11 N.E.C. 250, IN ALL CONDUITS WITH CIRCUIT CONDUCTORS. <br /> 3. ALL CONDUITS PENETRATING WALLS OR CEILINGS OF COOLERS, <br /> (E) (E) FIRE FREEZERS, OR REFRIGERATED PREP AREAS SHALL BE SEALED. <br /> I I GENERATOR RISER ' ' I 1 ' ' <br /> ROOM ROOM SEAL BOTH THE INTERIOR AND EXTERIOR OF THE PENETRATED <br /> SURFACE. <br /> 131 130 ° 1 ° ° 1 1 4. UNDER-SLAB CONDUIT IS TO BE INSTALLED A MINIMUM OF 4"P)-- <br /> - - +- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ° - - - - - - - - BELOW THE BOTTOM OF THE CONCRETE SLAB. ALL ELBOWS SHALL <br /> BE RIGID METAL CONDUIT OR INTERMEDIATE METAL CONDUIT. <br /> POWER MONITORING PANEL 5. CONTRACTOR SHALL PROVIDE UPDATED TYPED PANEL SCHEDULES <br /> (E)INCOMIIIING PNONE SERvic �O (E) PANEL LP IN ALL EXISTING ELECTRICAL PANELS TO REMAIN, REFLECTING <br /> ° (N) PANEL HFJ ❑ �❑ <br /> FINAL SCOPE AND AVAILABLE SPARES AND UNUSED SPACES <br /> (E) <br /> PANEL LCR3 <br /> (DN - ° -A <br /> ❑ KEYED NOTES <br /> I I I LCR3-13 I I I <br /> M.9 3/4"C-2#12,#12G HA <br /> El (E) PAN L„HEM <br /> (E) ❑ O 2. CONTRACTOR SHALL PROVIDE AND INSTALL A DUPLEX <br /> ❑ ° <br /> ELECTRICAL RECEP'TIALE ON TOP OF THE LOWEST CORD OF JOIST. <br /> (E) P L LA (E) CONTRACTOR SHALL INSTALL OWNER PROCIDED CORD REEL ON 004 PROJECT N <br /> 1 ° ° ° ROOM <br /> 129 (E) PI/ ILLD <br /> RECEIVING THE BOTTOM OF THE LOWEST CORD OF THE JOIST. SET STOPPER <br /> o (E) PM L I AREA ON CORD REEL SO THAT THE RECEPTACLE DOES NOT RETRACT DRAWN <br /> ° El (E)MSB 126 ABOVE 10'-0” A.F.F.. JFML <br /> 0 0 3. CONTRACTOR TO INTERCEPT AND EXTEND EXISTING TOE KICK CHECKED <br /> ° o ° (E) CIRCUIT TO NEW CASE TOE KICK RECEPTACLES. BC <br /> RECEIVING 5. EXISTING DEVICES IN THE PIZZA AREA TO BE DISCONNECTED SUBMITTAL DATES <br /> (E) OFFICE rr DURNING RE-SKIN. CONTRACTOR TO PROTECT AND RETAIN <br /> PRODUCE 127 EXISTING CONDUIT AND CONDUCTORS UPON COMPLETION OF 06/11/20 <br /> O RECEIVING RE-SKIN. CONTRACTOR TO RECONNECT ALL DEVICES IN <br /> ❑ 142 o ❑� ° EXISTING LOCATIONS. CONNECT ALL DEVIICES TO EXISTING <br /> - - - (E) BULK - ❑ - - - - - - - - <br /> M CONDUIT AND CONDUCTORS. CONTRACTOR IS RESPONSIBLE FOR <br /> FOOD °° L OTB DATE <br /> CONDUIT AND CONDUCTORS. CONTRACTOR IS RESPONSIBLE FOR <br /> ENSURING ALL SYSTEMS ARE COMPLETE AND OPERATIONAL AT <br /> 143 OM THE COMPLETION OF CONTRUCTION. <br /> ° 23 6. PROVIDE AND INSTALL J-BOX MOUNTED AT BOTTOM OF JOIST, <br /> (E) TRANSITIONING TO 2W+G#10 S.O. CORD, TERMINATED ON LS-30R <br /> (E) (E) MEAT ° (E)DAIRY GROCERY RECEPTACLE. RECEPTACLE IS TO BE LOCATED AT 10'-0" A.F.F. o o <br /> PRE-CUT = COOLER FREEZER 3 <br /> D ° o MEAT (E) MEAT ° BLOOM 121 120 COORDINATE EXACT LOCATION IN FIELD WITH OWNER PRIOR TO o a -row o <br /> BOX E ROUGH-IN, RE: E4.2-6. w p F v o <br /> ROOM = PREP/W P ( ) ° ° ° ° w �a w ¢ a o <br /> 140 - ROO 133 1 GROCERY 7. RELOCATED SELF CHECKSTAND POWER POLE. CONTRACTOR TO o o W c0o a <br /> 0 INTERCEPT AND EXTEND EXISTING SELF CHECKSTAND CONDUIT, Z <br /> (E) MEAT 134 TRANSFER a a a Q o o m N <br /> D FREEZER ' 125 CONDUCTORS AND DATA CABLING TO NEW SELF CHECKSTAND. �, W <br /> a 10 CONTRACTOR IS RESPONSIBLE FOR ENSURING A COMPLETE AND o a 6 o o I w <br /> 141 OPERABLE SYSTEM. REFER TO SHEET E4.2 DETAILS 2 AND 3 FOR w w a a A A o co <br /> � d� O• U �U U� S °: ao <br /> _(N) TRANSFORMER TLC2 — (N)JUICE o <br /> 00 COOLER �z�Qao �x <br /> � - ❑❑ I 1 I I I POWER POLE INSTALLATION. <br /> � � n O ■ 8. RELOCATED SELF CHECKSTAND ATTENDANT STATION POWER 6 w a z o <br /> D 10 w <br /> N PANEL LC2 E N TRANSFORMER TLRS 10 122 O o W a o <br /> ( )IA ( ) E) (E) DELI ELI ( ) O 0 ■ POLE. CONTRACTOR TO INTERCEPT AND EXTEND EXISTING00 <br /> SERVICE N PANEL LR4 z ' <br /> (E) PANEL HD (N) o VICE WRAP LER ® ( ) <br /> (E) PANEL LC CHICKEN N PANEL LRS�� E PANEL LB ° N TRANSFORMER TLR1 ( ) H o Ln <br /> co <br /> OO ❑ ❑ /�/�/ I,R1-41 CABLING TO NEW ATTENDANT STATION. CONTRACTOR IS w a x o <br /> ATTENDANT STATION CONDUIT, CONDUCTORS AND DATA x w o x H <br /> 136 35 ( ) �` � ) TK � N PANEL LRI A � zao <br /> D (E) PANEL LF SEC 1 COOLER ❑ ° o <br /> 37 ❑ ❑ � 3/4"C-2#12,#12G RESPONSIBLE FOR ENSURING A COMPLETE AND OPERABLE � o� � o <br /> K (E) PANEL LF SEC 2 139 ❑❑❑❑❑❑❑❑ K SYSTEM. REFER TO SHEET E4.2 DETAILS 2 AND 3 FOR POWER <br /> ° ° IN I POLE INSTALLATION. <br /> PRODUCE ° XIT (N) TRANSFORMER TLR4 ° w ° <br /> 9. NEW SELF CHECKSTAND POWER POLE. CONTRACTOR TO ROUTE <br /> VV\ (N) TRANSFORMER TLR3 10 a � <br /> COOLER ❑ �- _ __ __ __ __ __ __ __ __ __ �- - 132 Tx MC CABLE FROM CHECKSTANDS UP DOUBLE STRUT POWER POLE W O <br /> ----------------------------- - - - - - - - - - - - --- TO ROOF STRUCTURE AND TO PANEL. FOLLOW EXISTING SELF = <br /> 144 ° ° I I I I I I I I I � � � <br /> RE: E4.2 -4 CHECKSTAND MC CABLE ROUTING TO PANEL. REFER TO SHEET o <br /> E4.2 DETAILS 2 AND 3 FOR POWER POLE INSTALLATION. co <br /> ^ '� <br /> 0 o Tx 10. PENDANT MOUNT TRANSFORMER FROM BUILDING STRUCTURE O ('3 ❑ � <br /> o o o o ° ° ° ° LR2-41 ° ABOVE. SECONDARY CONDUCTOR LENGTH MUST NOT EXEED 25' ('� — ❑ <br /> O 3 3 0 3 0 0 3/4"C-2#12,#12G 1 a 11. REPLACED PRODUCE MISTER. CONTRACTOR TO INTERCEPT AND O U = Q, <br /> )owlLB-12 LB-10 LB-8 LB-6 J <br /> o EXTEND EXISTING CONDUIT AND CONDUCTORS FOR PRODUCE V � O <br /> TK TK ° �(N) PANEL LR3 MISTER TO NEW LOCATION. ❑ I w <br /> D J J J J (N) PANEL LR2 ° 12. PROVIDE AND INSTALL J-BOX MOUNTED AT BOTTOM OF JOIST, Z ❑ <br /> (E) ° ° Tx Tx Tx TRANSITIONING TO 3W+G#10 S.O. CORD, TERMINATED ON L14-30R w W ❑ cfl <br /> PRODUCE ° RECEPTACLE. RECEPTACLE IS TO BE LOCATED AT 10'-0"A.F.F. y �_ O <br /> DRY 0 0 °' 0 1 1 1 1 a CONTRACTOR SHALL PROVIDE 15'-0" S.O. WHIP FOR MOBILE < �. ❑ <br /> D ROOM <br /> 0 0 0 0 — J MERCHANDISER PLUG, 3W+G#10, WITH L14-30P. FIELD INSTALL W Q <br /> ° Tx , NEW PLUG AND S.O. WHIP ON MERCHANDISER. COORDINATE Q L U) O <br /> 145 LH-44 ° <br /> R3-41 (N) TRANSFORMER TLR2 10 EXACT LOCATION IN FIELD WITH OWNER PRIOR TO ROUGH-IN, d O <br /> 3/4"C-2#10,#10G 3/4"C-2#12,#12G RE: E4.2-5. _ o <br /> D SL03 JL O <br /> J 10 C w <br /> � a Q � O <br /> �(N) PANEL LR6 TK _ <br /> � o 0 <br /> (DH - - - - - - - - - - - - f - - - - - - - - - - - - - - - - - - - - - - <br /> ® o <br /> I I I I I I I <br /> N TRANSFORMER TLR6 10 a <br /> Q�OFESS/pN9l F <br /> I I I I I I I <br /> ❑ ❑❑ ILLIAM BURTO <br /> o <br /> LB, 19 <br /> ❑❑ o �� o o 3/4"C-2#12,#12G C. <br /> ❑ 2 <br /> ❑❑I l �P <br /> yTF OF A\OQ� <br /> EF <br /> 0 0 0 0 0 o LB-21 <br /> 0 0 00 0 0 0 0 0 0 <br /> 0 0 0 0 0 =0' �O). <br /> 2 3/4"C-2#12,#12G 06/11/20 <br /> 0 0 1 1 1 0 o i 1 2 <br /> 00000 <br /> 00 00 — — — — — — — — — — — — — — — — — — — — — — — — — — — — <br /> I <br /> 0 0 0Lj <br /> icto, <br /> LB-230 0 0 0 00 0 0 00]0.0.0 0 0 0 0 00 3/4"C-2#12,#12G <br /> 0 <br /> 2 2 <br /> 0 0 <br /> I I I I I <br /> 0 0 o O <br /> (E)MAIN <br /> 0 0 0 0 o SALES LB-25 • <br /> - - - - - - - - - - - - - - - o 00- o - - - - - - - - - - - - - - - - - - 0 0 0 0 100 3/4"C-2#12,#12G O <br /> 00 0 0 0 2 2 a <br /> I I I I 1 I W <br /> LB-27 <br /> 2 3/4"C-2#12,#12G C <br /> — - - - - - - - - - J- 1 <br /> - - - - - - - - - - - - - - - - - - - $ <br /> 0 0 0 0 <br /> O O I I I I I O <br /> O <br /> I I I I I <br /> ti- <br /> 511 - - - - - - - C.9 0 <br /> 11 I I I 15-2 I <br /> o <br /> LF-38 LF-40 _ 9 9 <br /> 3/4"C-2#10,#lOG 3/4"C-2#10,#10 ° <br /> I I I I I I I <br /> I <br /> 6 6 _ 9 9 _ <br /> ° <br /> Lo 18'-10" 29'- " `o FM (E) <br /> 7 7 BAKERY <br /> �; ❑ �; 119 <br /> JB-13,15 ❑ 7 Irn T T T [T IT T <br /> O 1 0 0 � � 1 �' 3/4'C-3#10,#lOG 1 1 1 1 1 ❑ <br /> 3.1 8 E E <br /> O O <br /> I I I 12 _ , I I O <br /> �., JANITORS CUSTOMER <br /> Fn CLOSET SERVICE (E) ❑ <br /> ° <br /> 103 STORAGE TAIRS <br /> 00 <br /> -.1 111 112 <br /> - - - - - - - SL05 -LCR-57 <br /> ❑ 00 O F 3/4"C-2#12,#12G (E) PANEL LH SEC2PY9 , <br /> 0 O 0 0 0 0 O 0 0 0 (E) PANEL LJ-A (E) PANEL LJ-B ❑ 9 10 <br /> - - - - - - - - - - - - - - ° LCR-55 <br /> E PIZZA E) I 3/4"C-2#12,#12G <br /> O SL16 <br /> ❑ O C <br /> 0 0 0 ❑ 10 ) (E) (E') (E') <br /> (E) CART I I )MEN � (E) PANEL HSL <br /> 0 0 ❑ (E) 0 5 CUSTOMER O STROO BAKEY BAKERY <br /> ❑ (E) EX SERVICE (E)BOOK FREEZER COOLER (E PANEL LCR1 O <br /> STORAGE ❑ J❑ EST (E) PANEL LCR2 (E) PANEL HC <br /> ENTRY0 0 15 <br /> 146 101 ❑� 102 1 O L ) I Z (E) 1 KEEPIN 1 117 118 ) <br /> u PREP. 00 E GROCERY 113 0 0 (E) PANEL LEM O <br /> TRANSFER O <br /> I I I I I I l0 I I ANE <br /> ❑ 108 ® (E) PANEL LG1 <br /> �� ❑ o o (E)„PANEL LG2 <br /> ( A ❑ - - - - - - - A (E) PANEL MDL POO <br /> ( 1 <br /> IRS <br /> TIr <br /> SHEET TITLE <br /> 1 104 1 Eo <br /> 1 2 3 4 5 5.6 6 6.2 6.4 7 7.3 8 10 11 ( A ❑ 1 1 - �O <br /> 9 � � <br /> POWER PLAN <br /> 9 10 <br /> a <br /> M POWER PLAN N0 7,4 MEZZANINE POWER PLAN N0 SHEET <br /> ri 3/32” = F-0" 1 3/32" = F-0" <br /> 04 <br /> N <br /> O <br /> N <br /> O� <br />