Laserfiche WebLink
REVISIONS <br /> ELECTRICAL LEGEND NO. DESCRIPTION DATE <br /> SYMBOL DESCRIPTION <br /> 1 2 3 4 5 6 7 8 9 10 11 CC CAREL HEOS MPX-PRO <br /> CONTROLLER <br /> I I I I I I I I I I I <br /> P - L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - � - - - - - - - - o 0 0 0 - - - - - - - L - P <br /> HM MASTER HEOS <br /> CONTROLLER <br /> °n <br /> IIIA <br /> WI HS SLAVE HEOS <br /> 0 o (0 I It <br /> CONTROLLER <br /> IE I I I I I I <br /> N o o - - - - - - - - - � - - - - - - � - - - - - - - - � - - - - - - � - - - - - - - - - - - - L - N BOSS SUPERVISORY <br /> NETWORK COMMUNICATION <br /> III LOOP WIRING: BELDEN 8762 <br /> I WI <br /> ' I I III I I 1 <br /> O A pLAN MASTER/ SLAVE <br /> COMMUNICATION <br /> 0 0 0 ° WIRING: BELDEN 3106A <br /> ARCH.PROJECT NO. <br /> 2004 <br /> \�\ of FIELD INSTALLED DRAWN <br /> ° o °u CONDENSING UNIT GH <br /> 0 CHECKED <br /> I� <br /> J <br /> FACTORY INSTALLED MC <br /> ° SOLOCHILL <br /> Er CONDENSING UNIT SUBMITTAL DATES <br /> I I I I I I I I I I I <br /> > ° o M 06/11/2020 <br /> I <br /> L (E) BULK L <br /> FOOD ° o <br /> TBD TE <br /> 143 B6 CS GENERAL NOTES <br /> BS C4 B4 B3 B3 B2 B2 B1 B1 A7 A6 AS <br /> PRE-CUT (E) (E) 1. CONTRACTOR SHALL SUPPLY, INSTALL, AND TERMINATE ALL BOSS <br /> MEAT PREP[ RAP (E) M T ° (E)DAIRY GROCERY SUPERVISORY NETWORK COMMUNICATION LOOP AND o x <br /> ° 21 <br /> ROOM RODo BLO REFRIGERATION COOLER FREEZER MASTER/SLAVE PLAN NETWORK WIRING. o z <br /> C10 (E)MEAT 140 1 BO PLATFORM ° _ _ ° ° 121 - 120 2. THE MAXIMUM LENGTH PER EACH INDIVIDUAL COMMUNICATION ° <br /> woH°� oz <br /> o FREEZER BS Q 13 SEE R3 LOOP SHALL NOT EXCEED 500 METERS (1640 FT). a a F <br /> 141 B6 CS i1 3. SERIAL NETWORK CABLE SHALL BE CAREFULLY ROUTED AWAY FROM z a z z <br /> PRO U B4 I I POWER CABLES OR OTHER HIGH ELECTRICAL NOISE ENVIRONMENTS. <br /> A8 C3 � FTS S �o�F w _ .o <br /> CO LE C4 II I 1 024 13.025 13.026 DO NOT CREATE SLACK COILS AT TERMINATIONS. x z z I <br /> E DELI I17F �o �"Q�°� zo <br /> � � O SL6.1 SL6.2 SL6.3 4. DAISY CHAIN LAYOUT SHALL BE USED FOR NETWORK w w w �w Q o°` <br /> Rci N) I �I H ��� �� RAPL - I (N)JUICE COMMUNICATION. BRANCHES OR STAR CONFIGURATIONS ARE NOT " a Q z 3 N <br /> 135 I' COOLER TO BOSS PANEL z a A A o a Z. I z y 3 6 <br /> CH KEN PERMITTED. ¢ w = N <br /> 6 � 1 122 COMM LINE 13 u� ww . <br /> Ll CO LER I SERVICE SE VIC TO BOSS PANEL' 5. DRAWING SHOWS CONNECTIONS FOR EACH SEGMENT,NOT <br /> II a DELI 0 FOOD C6 COMM LINE 11 �' C3 - - -I, - - - - - - , SM2.2 ' - NECESSARILY CABLE ROUTING. CASES FED BY UNDERGROUND PIPING <br /> 33:9] <br /> SM11.1 I 1 137 B7 (11.020) (11.016) 16) SM2.6 SM2.5 SM2.4 SM2.3 SM2.1 SHALL HAVE NETWORK CABLING RUN IN SAME UNDERGROUND <br /> SL17.1,4 SL 17.2,3 SL6.1,4 SL .2,3 IFu ll� I I (1 ) --� (13.01 �/ 1(13.01 �/ (13.01 �/ (13.01 (13.01 �/ (13.01 ROUTING. y <br /> K - - - C1 1 - - - - - - - - - - - - - - - - xs xs xs xs xs SL7.1 - - - K 6. ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL ALL o o <br /> ° xs Hs I'llHs Hs SM1.1 Hs �1 Hs s s xs RACEWAYS AND CONDUIT REQUIRED BETWEEN NON-ADJACENT <br /> SM1 ° ° ° ° C] C7 B8 (11.024) 01 3.017 SL8.1 3.018 SL8.2 3.019 SL8.3 3.020 �\ 3.021 �� 1 .022 SL8.6 (1 ) CASES. Ctrl <br /> SL22.1 SM9.1 SM9.2 SM 10.1 SM 10.2 SM 10.3/ SM 10.4 SL8.4 SL8.5 r� <br /> / / TO BOSS PANEL - - - SL5.1 M o <br /> o / COMM LINE 12 <br /> C11 Q Ln <br /> KEY NOTES WLy <br /> ° Hs 12. 2s SL17.2 o <br /> SLI (12.01 SL11.2 12.01 ) SL11.1 (1 .ol SL10.3 12.0 SL10.2 12.01 SL10.1 12.01 O o <br /> o C9 C8 xs 0A xs X14) ) ( > ( ( ( ( ) <br /> SL21.3 SL20.3 SL17.1 SL17.3 HS HS M HS HS SL9.1 SL4.1 N <br /> (E) A9 SL19.3 SL18.3 a m <br /> PRODUCE C9 C8 A9 (lo.o Hs *SL21.2 (lo.o Hs ® SL20.2 , ' SL19.2 SL18.2 HsSL17.4 SL12.1 � xs � xs �� � xs � xs � 1. COMMUNICATION WIRE RUN IN UNDERGROUND CONDUIT. SEE � � � H Q <br /> O O 2.023 SL13.1 2.022 SL13.2 .021 SL113.3 020 SL14.1 .019 SL14.2 018 SL14.3 (1 ) ELECTRICAL PLANS. CONDUIT SHALL STUB UP NO MORE THAN 12" V� ~ <br /> ( > FROM REFRIGERATION STUB UP LOCATIONS SHOWN ON R1. ■ * w <br /> DRY 1 1 C9 C8 A9 SL21.4 � SL20.4 Hs . 14) xs . 12) �\ 1 ,\ _ - I - - - - - - w � <br /> ROOM ° o SL19.4® S 18.4 - - - ul Z <br /> 145 (10.0 xs (10.0 xS W cn <br /> 0 A9 ° L21 1 b L20.1 SL 19.1 b SL18.1 O W Q <br /> C9 C8 ° S , ° S ° <br /> 0 o° �1 \ SL3.1 Qcc <br /> Lo <br /> (K) - - - - - - - - - - o - i1 - q - � - - - - ° - - - - - �12 <br />