My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
755
>
2300 - Underground Storage Tank Program
>
PR0508090
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 9:29:42 AM
Creation date
9/24/2020 9:29:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0508090
PE
2361
FACILITY_ID
FA0007938
FACILITY_NAME
CHEVRON #208117**
STREET_NUMBER
755
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
24202029
CURRENT_STATUS
01
SITE_LOCATION
755 S TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
190
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ogit1 <br /> SAN ;JOAQUIN Environmental Health Department <br /> C 0 U %J JC Y <br /> Unci rgVound Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> CHEVRON 4208117 " (209) 830=0370 February 07 , 2019 <br /> Facility Address: ID: <br /> 755 S TRACY BLVD, TRACY, CA 95376 CERS ERS ID: <br /> Inspection Contact: Title: Phone: <br /> Kristina Ramirez Station manager (209) 830"0370 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION - Operating Permit 2361 - UST FACILITY <br /> Consent For: Consent Given By: <br /> ❑ Inspection ❑ Photos ❑ Samples Kristina Ramirez. Station manager <br /> Service Technician Onsite: Exp, Date : Designated Operator: Exp, Date: <br /> Jesus Saldivar 06/16/2019 Rayana Black 01 / 19/2020 <br /> Service Technician Manufacturer's Training : <br /> Veeder Root, 05/01 /19, VMI , 11 /20/19, SB , 01 /31 /20 <br /> CCR = Title 23 California Code or Ragulaltons HSC = eahh and Safely Cade CFR = Code of Federal Regulations <br /> V = Violation R = Repeat violation COS = Corrected on site during inspection <br /> fie Review <br /> 101 HSC 25284 Failed to Obtain a permit to operate from the EHD Including but not limited to unpaid permit fees a V o R a COS <br /> 102 HSC 25284(a) (3) (A)/(B) No written agreement between lank owner and tank operator to monitor the tank system o V u R ; COS <br /> 103 HSC 25292. 21 25293, 30 Failure to submit and maintain complete and current financial responsibility documents a V u R n COS <br /> 104 CCR 2711 UST operating permit application for facility and tank Information not submitted or current V a R a COS <br /> 105 CCR 2632(d)(1 ), Failed to have an approved UST monitoring plan o V a R a COS <br /> 2634 (d) <br /> 106 CCR 2632(d)(2) , Failed to have an approved UST response plan 0V - R n COS <br /> 2634 (e) <br /> 107 CCR 2632(d)( 1 )(C) Plot plantsite map not submitted or failed to completely show where monitoring is performed n V - R COS <br /> 108 CCR 2837, 2638(e), Failed to notify the EHD 43 hours prior to conducting testing ❑ V R a COS <br /> 2643(g) <br /> 109 CCR 2637(a-d), 2712 Faded to test secondary containment, or railed to maintain lest records for 36 months in V zi R e COS <br /> 110 CCR 2637 (e), 2637(f) Faded to submit ' Secondary Containment Testing Report Form' within 30 days atter the lest „ V , R COS <br /> 111 CCR 2638(a) 8 (b) , Failed to test monitoring and leak detection equipment annually o V R o COS <br /> 2641 6) <br /> 112 HSC 25293 Failure to maintain UST records to enable the UPA to determine whether the UST is in compliance e V o R a COS <br /> 113 CCR 2638 (c) , 2638(d) Failure to submit " Monitoring System Certification Form" within 30 days of completion of the test a V c R COS <br /> 114 CCR 2836(Q (3), 2643(c) No 0. 1 gph annual line integrity test for pressurized piping or within 30 days after repair a V o R a COS <br /> (3) <br /> 115 CCR 2715 (a) (1 ) (B), " Designated Underground Storage Tank Operator Identification Form" not submitted within 30 days o V o R o COS <br /> 2715(a) (3) <br /> 116 CCR 2715 Designated operator, service tech or installer did not possess current ICC certification o V o R a COS <br /> 117 CCR 2663, 2712(b)(6) Failure to comply with tank lining, recordkeeping, and inspection requirements a V o R c COS <br /> 118 CCR 2715(a) ( 1 )(A) , Failure to submit the "Underground Storage Tank Statement of Understanding and Compliance Form' a V c R n COS <br /> 2715(a) 2) <br /> 119 HSC 25299(a)(8) , Documents were falsified or misrepresented o V r R n COS <br /> 25299(b) (7) <br /> 120 CCR 2635(d) Felled to submit UST Certification of Installalion(Modificalion n V ❑ R uCOS <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report o V n R o COS <br /> 122 CCR 2631 , 2640. 1 , Failure to submit and/or maintain documentation regarding compatbikty for UST system components c V R COS <br /> 2665 , 2711 <br /> FA0007938 PR0508090 SC001 02/0712019 <br /> EHD 2MI Rev 09/28x2018 Page 1 of 6 Underground Storage Tank Program OIR <br /> 1868 E Hazelton Avenue I Stockton . California 95205 1 T 209 468-3420 1 F 209 464 -0138 I www s)cehd. com <br />
The URL can be used to link to this page
Your browser does not support the video tag.