Laserfiche WebLink
SANN J O Q � ( ( N Environmental Health Department <br /> �J j-� 'C C) �� lU (I y31 In <br /> I Mail <br /> _ <br /> Ion 1711 <br /> Uncielt+gtound St iagye„farikF>roglrtam In �pW1611 R��ork <br /> .. <br /> Facility Name: Facility Address: <br /> CHEVRON #208117 ` ” IIIIIIIIIIIIIIIIIJ bate: <br /> 755 S TRACY BLVD, TRACY February 07 , 2019 <br /> Item 0 <br /> Remarks <br /> 109 CCR 2637(a-d ) , 2712 Failed to test secondary containment, or failed to maintain test records for 36 months. <br /> Under dispenser containments 1 /2 , 3/4 , 516 , 7/8 and 9/10 were installed under service request #SR0078631 on <br /> 4/ 12/ 18 and six month testing was due by October 2018. Testing has not been completed and is 3 months past <br /> due . Secondary containment testing is required at the time of installation and six months after installation and at <br /> least every 36 months after. Immediately schedule secondary containment testing for UDC 1 /2 , 3/4 , 5/6 , 718, 9110 , <br /> 87 product and 91 product . Provide 48 hours notification to the EHD , <br /> This is a Class II violation . <br /> 124 CCR 2637 . 2(d&e), 2665(a&b) "Overfill Prevention Equipment Inspection Report Form " not submitted within 30 days <br /> of inspection . <br /> overfill prevention equipment inspection report was performed on 11 /21 / 18 and a test report was submitted on <br /> 1 /18/19 , 28 days late . A copy of the test report must be submitted within 30 days of the tests . Take all necessary <br /> precautions to ensure testing and submittal of test reports are performed in a timely manner, <br /> This is a minor violation . <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days , <br /> On the 10/31 /18 designated operator (DO ) inspection report under : <br /> -Section VI <br /> The OWNER / OPERATOR failed to provide a name, signature, and date within 48 hours of receiving the DO report <br /> under the ACKNOWLEDGMENT OF COMPLIANCE ISSUES section . The designated operator (Vivian Vargas ) and <br /> not the operator signed the 10/31 / 18 DO report on 10/31118. Ensure that the owner/operator of the facility reviews <br /> section III and signs section VI of the DO report . <br /> -Section X <br /> The DO failed to mark NO under the question "Has the overfill prevention equipment Inspection been completed <br /> within the past 36 months?" The overfill prevention equipment inspection was conducted on 11 /21 / 18. <br /> During the monthly inspection , the designated operator shall review the alarm history for the previous month , check <br /> that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br /> documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br /> inspections at least once every 30 days at this facility and are including all of the required information on the reports . <br /> This is a minor violation , <br /> 313 HSC 25290. 11 25290, 2 , 25291 Failure to construct, operate , and maintain primary containment as product-tight. <br /> Seepage was observed in the 91 product union in Under dispenser containment 1 /2 , 3/4 and 9/10, indicating a leak <br /> in the primary piping . All primary containment for the UST system must be tight. Immediately have a properly <br /> licensed , trained , and certified contractor repair or replace the failed component under permit and inspection of the <br /> EHD . <br /> This is a repeat violation , Class II , <br /> FA0007936 PROSOB090 SC0o1 02/07/2019 <br /> EHD 23-0i Rev, 09!282018 Page 4 or 5 <br /> r3 Underground Storage Tank Program Dlft <br /> 1868 E. Hazelton Avenue Stockton , California 952051 T 209 468-3420 1 F 209 464 -0138 www, sjcehd . com <br />