My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1234
>
2300 - Underground Storage Tank Program
>
PR0516248
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/3/2024 1:20:32 PM
Creation date
9/25/2020 11:08:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0516248
PE
2361 - UST FACILITY
FACILITY_ID
FA0012532
FACILITY_NAME
CHEVRON STATION #209167
STREET_NUMBER
1234
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120016
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
1234 E YOSEMITE AVE MANTECA 95336
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAHI <br />CQU NTY <br />' SS grows heir <br />Environmental Health Department <br />Time In: <br />Time Out: <br />Underground Storage Tank Program Service Request Inspection Report <br />Name of Facility: CHEVRON STATION #209167 <br />Date: 09/13/2019 <br />Address: 1234 E YOSEMITE AVE, MANTECA 95336 <br />Requestor: LIDDY MCKENZIE, GETTLER RYAN INC. <br />Telephone: (925) 551-7555 <br />Program Element: 2308 - UST RETROFIT <br />Request #: SR0080291 <br />Inspection Type: 298 - UST RETROFIT REPAIR INSPECTION <br />Onsite Service Technician: Raymond Simms <br />ICC Service Tech/Installer Exp. Date: 06/25/2020 <br />Manufacturer training: VMI, 12/10/20; VR, 10/04/20 <br />OVERALL INSPECTION NOTES AND COMMENTS <br />NOTES <br />On site for : <br />-verification of the dispenser foot prints contained by the under dispenser containment (UDC) sumps and any potential leaks <br />from piping and fuel filters drainage into UDC's. Fuel filters are out of the UDC compartment cannot drain directly into UDC's <br />require deflector plates to be installed in all UDC's <br />-Leak detector test conducted . 87 and 91 passed <br />-Verify sensor functionality <br />Veeder root sensors #208 in all UDC's and #209 in STP sumps and they shutdown STP in case of leak. <br />-Installation of new red jacket line leak detectors <br />-New module to existing veeder root monitoring panel and System cold start conducted. <br />-Witness Secondary containment testing on Vacuum - Passed <br />This facility is approve to operate the UST system pending, final inspection by EHD of deflector plates installation at all UDC's, <br />update of CERS records and receipt of all test results . <br />The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the current hourly rate. <br />Received by: <br />EH Specialist: PAUL NSO <br />Name and Title: Desmond Pisano, Foreman <br />Phone: (209) 468-3432 <br />FA0012532 SR0080291 SC298 09/13/2019 <br />EHD 23-01 Rev. 06/30/15 Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.