Laserfiche WebLink
tiff eurofins <br />Calscience <br />Glossary of Terms and Qualifiers <br />Page 8 of 10 <br />Work Order: 17-12-1281 Page 1 of 1 <br />Qualifiers Definition <br />See applicable analysis comment. <br />< Less than the indicated value. <br />> Greater than the indicated value. <br />1 Surrogate compound recovery was out of control due to a required sample dilution. Therefore, the sample data was reported without further <br />clarification. <br />2 Surrogate compound recovery was out of control due to matrix interference. The associated method blank surrogate spike compound was <br />in control and, therefore, the sample data was reported without further clarification. <br />3 Recovery of the Matrix Spike (MS) or Matrix Spike Duplicate (MSD) compound was out of control due to suspected matrix interference. The <br />associated LCS recovery was in control. <br />4 The MS/MSD RPD was out of control due to suspected matrix interference. <br />5 The PDS/PDSD or PES/PESD associated with this batch of samples was out of control due to suspected matrix interference. <br />6 Surrogate recovery below the acceptance limit. <br />7 Surrogate recovery above the acceptance limit. <br />B Analyte was present in the associated method blank. <br />BU Sample analyzed after holding time expired. <br />BV Sample received after holding time expired. <br />Cl See case narrative. <br />E Concentration exceeds the calibration range. <br />ET Sample was extracted past end of recommended max. holding time. <br />HD The chromatographic pattern was inconsistent with the profile of the reference fuel standard. <br />HDH The sample chromatographic pattern for TPH matches the chromatographic pattern of the specified standard but heavier hydrocarbons <br />were also present (or detected). <br />HDL The sample chromatographic pattern for TPH matches the chromatographic pattern of the specified standard but lighter hydrocarbons were <br />also present (or detected). <br />J Analyte was detected at a concentration below the reporting limit and above the laboratory method detection limit. Reported value is <br />estimated. <br />JA Analyte positively identified but quantitation is an estimate. <br />ME LCS Recovery Percentage is within Marginal Exceedance (ME) Control Limit range (+/- 4 SD from the mean). <br />ND Parameter not detected at the indicated reporting limit. <br />Q Spike recovery and RPD control limits do not apply resulting from the parameter concentration in the sample exceeding the spike <br />concentration by a factor of four or greater. <br />SG The sample extract was subjected to Silica Gel treatment prior to analysis. <br />X % Recovery and/or RPD out -of -range. <br />Z Analyte presence was not confirmed by second column or GC/MS analysis. <br />Solid - Unless otherwise indicated, solid sample data is reported on a wet weight basis, not corrected for % moisture. All QC results are <br />reported on a wet weight basis. <br />Any parameter identified in 40CFR Part 136.3 Table II that is designated as "analyze immediately" with a holding time of — 15 minutes <br />(40CFR-136.3 Table ll, footnote 4), is considered a "field" test and the reported results will be qualified as being received outside of the <br />stated holding time unless received at the laboratory within 15 minutes of the collection time. <br />A calculated total result (Example: Total Pesticides) is the summation of each component concentration and/or, if "J" flags are reported, <br />estimated concentration. Component concentrations showing not detected (ND) are summed into the calculated total result as zero <br />concentrations. <br />7440 Lincoln Way, Garden Grove, CA 92841-1427 • TEL: (714) 895-5494 • FAX: (714) 894-7501 <br />I <br />U <br />0 <br />5 <br />v <br />