Laserfiche WebLink
January 9, 2018 <br />Pactiv Packaging Inc. <br />Lab ID : STK1755503 <br />Customer :3-17694 <br />Inorganic - Metals QC <br />Organic QC <br />12/20/2017:215154 All preparation quality controls are within established criteria, except: <br />�0 <br />The following note applies to Mercury: <br />245.1 <br />435 Sample matrix may be affecting this analyte. Data was accepted based on the LCS or CCV recovery. <br />The following note applies to Mercury: <br />435 Sam le matrix may be affecting this analyte. Data was accepted based on the LCS or CCV recovery. <br />5030B <br />12/18/2017:215032 All preparation quality controls are within established criteria, except: <br />The following note applies to Silver, Barium, Molybdenum, Lead, Thallium, Zinc: <br />3010 <br />435 Sample matrix may be affecting this analyte. Data was accepted based on the LCS or CCV recovery. <br />8260B <br />The following note applies to Silver, Barium, Chromium, Molybdenum, Nickel, Lead, Antimony, Thallium: <br />430 Post Digestion Spike (PDS) not within Acceptance Range (AR) because of matrix interferences <br />affecting this analyte. Data was accepted based on the LCS recovery. <br />Organic QC <br />Inorganic - Wet Chemistry QC <br />4500-H B 12/22/2017:215261 All preparation quality controls are within established criteria. <br />4500HB 12/22/2017:219142 All analysis quality controls are within established criteria. <br />Page 2 of 21 <br />12/21/2017:215201 All preparation quality controls are within established criteria, except: <br />�0 <br />The following note applies to 4-Nitrophenol, Phenol: <br />436 Blank Spike (BS) not within Acceptance Range (AR). Data was accepted based on the LCS or CCV <br />recovery. <br />12/15/2017:215015 All preparation quality controls are within established criteria, except: <br />5030B <br />The following note applies to 4-Bromofluorobenzene: <br />435 Sample matrix may be affecting this analyte. Data was accepted based on the LCS or CCV recovery. <br />12/15/2017:218850 All analysis quality controls are within established criteria, except: <br />8260B <br />The following note applies to 1,1,2,2 -Tetrachloroethane, 1,2,3-Trichlorobenzene, 1,2,4-Trimethylbenzene, <br />2-Chlorotoluene, 4-Chlorotoluene, Carbon Disu: <br />360 CCV above Acceptance Range (AR). Samples which were non detect for this analyte were accepted. <br />8270C <br />12/28/2017:219419 All analysis quality controls are within established criteria. <br />Inorganic - Wet Chemistry QC <br />4500-H B 12/22/2017:215261 All preparation quality controls are within established criteria. <br />4500HB 12/22/2017:219142 All analysis quality controls are within established criteria. <br />Page 2 of 21 <br />